Low level programming
Functionality
Hold
Econo
key for 20 seconds, 1st parameter will appear (Up/Down keys modify values)
Duration
Press
Econo
key to display next parameter, System will reset after last parameter.
Display
As table below,
Default values in bold.
Parameter
Display
Value of x
Pump #1
P1 x
1 = Single speed
2 = Dual speed
Pump #2
P2 x
0 = Not installed
1 = One speed
2 = Two speeds
Pump #3
P3 x
0 = Not installed
1 = One speed
Blower
bL x
0 = Not installed
1 = One speed
2 = Two speeds
3 = three speeds
Light
LI x
0 = Not
1 = 12 VAC
2 = 12 VAC
3 = 120 VAC
4 = INTERNAL
installed
(single
(three
Fibber box
intensity)
intensity)
Ozone
O3 x
0 = Not installed
1 = on only
2 = always on
3 = on with
during Filter
the circulation
cycle
pump
Circulation Pump
CP x
0 = Not installed
1 = regulated
2 = always on
3 = always on
(with spa
but off when
temperature)
2 degrees over
set point
Filtration cycle
FC x
1 = filtration cycle enable
2 = Filtration cycle replaced by a purge cycle
Pressure switch
PS x
0 = with pump one
1 = with the circulation pump
(CP can not be at 0)
Time out output
To x
0 = 20 minutes
1 = 30 minutes
2 = 40 minutes
Current pump #1
C1 x
Select the current of the pump #1 (1 – 15)
Current pump #2
C2 x
Select the current of the pump #2 (1 – 15)
Current pump #3
C3 x
Select the current of the pump #3 (1 – 15)
Current blower
Cb x
Select the current of the blower (1 – 8)
Current heater
CH x
Select the current of the heater (12 – 23)
1.8 Jumper configuration
Jumper Number
Function
Position 1 (Left)
Position 2 (Right)
JMP-1
Input Current Mode
HC
The Heater will be
LC The Heater must not
turned off if more than
be turned on if ANY
two pumps are activated
pumps (1, 2 or 3) are at
on high speed.
high speed.
JMP-2
Keypad
Keypad with 10 keys
Keypad with 8 keys
JMP-3
TSC
TSC-4
TSC-8
JMP-4
TSC
TSC-47
TSC-8
Note: Keypad with 10 keys mandatory if Pump #3 or RTC required. Factory Default values in bold (for CP installed).
*If CP not installed is chosen then software will automatically default to Pump #1.
46
PA C I F I C H O T T U B S O W N E R ’ S M A N U A L
Summary of Contents for Pacific 2004
Page 54: ...55 PACIFIC HOT TUBS OWNER S MANUAL PHT 1000 PHT 2002 ...
Page 55: ...56 PACIFIC HOT TUBS OWNER S MANUAL PHT 1000 PHT 2002 ...
Page 56: ...57 PACIFIC HOT TUBS OWNER S MANUAL LXT Models equipped with Aqua Stealth ...
Page 57: ...58 PACIFIC HOT TUBS OWNER S MANUAL LXT Models ...
Page 58: ...59 PACIFIC HOT TUBS OWNER S MANUAL ULXT Model ...