2104349 rev. AD
Page 1
–19
SP effect
DP Zero per 1500 psi:
± 0.03% of URL (3200 psi maximum)
DP Span per 1500 psi:
± 0.1% of Reading (3200 psi maximum)
Temperature
Operating range
-80
F to 750
F (-62
C to 339
C)
Accuracy
± 0.35
F (± 0.2
C)over operating range (as shipped from factory)
± 0.2
F (± 0.12
C) repeatability over operating range (after single point field calibration)
1.2.5 Display assembly
The G4 EX display assembly (see Figure 1
–16) has a dedicated interface to the
main processor board from the 4x16 LCD via a 14-pin connector.
The display utilizes four lines by 16 characters. The user can then customize the
annunciators based on their own specific needs. The alarm codes and
annunciators communicate a basic message(s) to the user and indicate a need for
further attention. These codes are location dependent and may mean different
things, based upon which character space the code appears in. These are also
user configurable.
Figure 1
–16 Liquid Crystal Display (LCD) assembly
1.2.6 Resistive temperature detector (RTD)
Totalflow offers a choice of two RTD options. The 100 OHM Platinum RTD
measures real-time flowing temperature of the gas.
1.2.6.1
Standard RTD
The standard RTD is not DIV 1 approved; therefore, this RTD may only be
installed and used in general purpose areas.