Devices 95
-Bitword: Parameters with bitwords. You can edit the bit values and texts using the
Edit List
button.
•
Index - Displays the parameter index in group.index format. Max value is 255.255
•
WP - Displays whether the parameter is write protected.
•
Pointer - Allows you to enable target parameter pointer selection in web UI.
•
Unit - Displays the unit that is displayed in the parameter browser.
•
Internal type - Defines the parameter internal type as follows:
U16: Unassigned 16 bit integer
S16: Signed 16 bit integer
U32: Unsigned 32 bit integer
S32: Signed 32 bit integer
•
Scaling: Defines the scaling value to scale the value read from the drive
•
Decimals: Displays the number of decimals displayed in the parameter browser.
This is not used for any calculations.
•
Format: Defines the value format. For example dec for decimal, hex for hexa
decimal, and bin for binary.
Modbus/TCP gateway tab
The Modbus/TCP gateway tab contains a list of all connected drives which can be
accessed through the Modbus/TCP gateway.