Note
Action
Remove the
protection hood
in the upper end
of the balancing device.
4
Insert two
screws, M12x50
in the holes to
neutralize the spring force. Screw in the screws
until they have proper contact with the cylinder
inside.
5
The length of the cylinder is now locked and
the balancing device is unloaded. It should now
be possible to easily rotate the balancing
device.
xx1000001112
Attach a
lifting accessories
to the balancing
device.
Use the
hole
in the lifting ear.
6
xx1000001113
Remove the upper and lower
lock nuts
and
support washers
(2+2 pcs).
Note
Make sure that the shaft between the upper and
lower arm does not rotate when unscrewing the
lock nuts! The lock nut is locked with Loctite
243.
7
Art.no. is specified in
Fit the
auxiliary shafts
on the upper and lower
pivot shaft.
Fit the short auxiliary shaft on the upper shaft
and the longer on the lower shaft.
8
Stretch the
roundsling
.
9
Continues on next page
268
Product manual - IRB 6660
3HAC028197-001 Revision: S
© Copyright 2007-2018 ABB. All rights reserved.
4 Repair
4.5.3 Replacing the balancing device
Continued
Summary of Contents for IRB 6660
Page 1: ...ROBOTICS Product manual IRB 6660 ...
Page 8: ...This page is intentionally left blank ...
Page 18: ...This page is intentionally left blank ...
Page 48: ...This page is intentionally left blank ...
Page 108: ...This page is intentionally left blank ...
Page 172: ...This page is intentionally left blank ...
Page 366: ...This page is intentionally left blank ...
Page 386: ...This page is intentionally left blank ...
Page 388: ...This page is intentionally left blank ...
Page 394: ......
Page 395: ......