4 Repair
4.6.3. Replacement of motor, axis 3
3HAC027151-001 Revision: B
212
©
Co
py
rig
h
t 200
6-
200
8 ABB. All righ
ts reser
v
ed.
14. Refit the
cable gland cover
at the cable exit with
its two attachment screws.
Make sure the cover is tightly
sealed!
Shown in the figure
15. Refit the cover on top of the motor with its four
attachment screws.
Make sure the cover is tightly
sealed!
16. Remove the equipment used to unload the upper
arm.
17. Perform a leak-down test.
Detailed in section
.
18. Refill the gearbox with oil.
Detailed in section
19. Recalibrate the robot!
Calibration is detailed in a separate
calibration manual, enclosed with
the calibration tools.
General calibration information is
included in section
Calibration infor-
mation
.
20.
DANGER!
Make sure all safety requirements are met when
performing the first test run. These are further
detailed in section
cause injury or damage! on page 33
.
Action
Note
Continued