4 Repair
4.3.2. Replacement of cable harness, axes 4-6
93
3HAC022031-001 Revision: C
©
Co
py
rig
h
t 200
4-
200
8 ABB. All righ
ts reser
v
ed.
7. Fit the upper bracket securing the
cables to the arm house, using the two
attachment screws.
8. Fit the adapter plate to the harness by
using its two attachment screws (A).
xx0200000404
Note! Different robot versions are fitted with
different plate versions. Make sure the
correct one is used to avoid cable failure.
9. Fit all the screws securing the cable
gland.
This attaches the cable harness to the
frame.
Cables
•
A - Power
•
B - Power
•
C - Power
•
D - Customer
•
E - Signal
•
F - Signal
Note! Make sure that each cable is fitted
at the same position as the old ones,
otherwise the conduit entry will not be
watertight.
Note! Always use a new
sealing
and
combine it with a
flange sealing
(Loctite
574).
xx0200000402
.
10. Connect connectors R2.FB 4-6 to the
connection R2.SMB4-6 (B) on the SMB-
unit.
xx0200000400
Action
Note/Illustration
Continued
Continues on next page
Summary of Contents for IRB 2400/L