5 Calibration information
5.5. Updating revolution counters
3HAC022031-001 Revision: C
166
©
Co
py
rig
h
t 200
4-
200
8 ABB. All righ
ts reser
v
ed.
Step 2 - Storing the revolution counter setting with the FlexPendant
This procedure details the second step when updating the revolution counter; storing the
revolution counter setting with the FlexPendant (RobotWare 5.0).
8.
CAUTION!
If a revolution counter is incorrectly updated, it will cause incorrect robot
positioning, which in turn may cause damage or injury!
Check the calibration position very carefully after each update.
How to perform the check is detailed in section
Action
Note
Action
1. On the
ABB
menu, tap
Calibration
.
All mechanical units connected to the system are shown along with their calibration
status.
2. Tap the mechanical unit in question.
A screen is displayed: tap
Rev. Counters
.
en0400000771
3. Tap
Update Revolution Counters...
.
A dialog box is displayed, warning that updating the revolution counters may change
programmed robot positions:
•
Tap
Yes
to update the revolution counters.
•
Tap
No
to cancel updating the revolution counters.
Tapping
Yes
displays the axis selection window.
Continued
Continues on next page
Summary of Contents for IRB 2400/L
Page 1: ...Product manual Articulated robot IRB 2400 L IRB 2400 10 IRB 2400 16 M2000 M2000A M2004 ...
Page 2: ......
Page 8: ...Table of Contents 6 3HAC022031 001 Revision C Copyright 2004 2008 ABB All rights reserved ...
Page 191: ......
Page 192: ......
Page 193: ......
Page 194: ......
Page 195: ......
Page 198: ......
Page 199: ......
Page 202: ......
Page 203: ......
Page 205: ......
Page 226: ......