Removing the EIB board
Use this procedure to remove the EIB board.
Information
Action
DANGER
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
1
CAUTION
Always cut the paint with a knife and grind
the paint edge when disassembling parts
of a Clean Room robot! See
2
See the figure in :
•
Location of the Encoder Interface
board on page 148
Remove the
base cover
.
3
See the figure in:
•
Location of the Encoder Interface
board on page 148
Remove the attachment screws securing
the
plate
.
4
Pull carefully out the cable harnesss main
a little in order to reach the EIB board.
5
Disconnect the battery cable.
6
See the figure in:
•
Location of the Encoder Interface
board on page 148
Remove the
bracket
where the battery is
fitted.
7
Disconnect connectors:
•
R1.ME1-3
•
R1.ME4-6
•
R2.EIB.
8
See the figure in:
•
Location of the Encoder Interface
board on page 148
Remove the
EIB board
.
9
Refitting the EIB board
Use this procedure to refit the EIB board.
Information
Action
Clean Room robots: clean the joints that
have been opened. See
1
Tightening torque: 2 Nm.
Fit the EIB board.
2
See the figure in:
•
Location of the Encoder Interface
board on page 148
Reconnect connectors:
•
R1.ME1-3
•
R1.ME4-6
•
R2.EIB.
3
Continues on next page
Product manual - IRB 120
149
3HAC035728-001 Revision: N
© Copyright 2009-2017 ABB. All rights reserved.
4 Repair
4.3.3 Replacing the Encoder Interface board
Continued
Summary of Contents for IRB 120
Page 1: ...ROBOTICS Product manual IRB 120 ...
Page 8: ...This page is intentionally left blank ...
Page 90: ...This page is intentionally left blank ...
Page 114: ...This page is intentionally left blank ...
Page 224: ...This page is intentionally left blank ...
Page 250: ...This page is intentionally left blank ...
Page 254: ...This page is intentionally left blank ...
Page 264: ...This page is intentionally left blank ...
Page 270: ......
Page 271: ......