Removal, step 2 - Swing housing
Information
Action
CAUTION
Always cut the paint with a knife and grind
the paint edge when disassembling parts
of a Clean Room robot! See
1
A
B
xx0900000879
Bracket
A
Attachment screws (2 pcs)
B
Remove the
cable bracket
from the lower
arm.
2
Cut
cable ties
at motor axis 2.
3
Disconnect
connectors
:
•
R2.MP2
•
R2.ME2
4
xx1300001604
Remove the remaining
attachment screws
securing the swing housing.
5
If needed, use two screws to press the
swing housing out.
6
Continues on next page
Product manual - IRB 120
173
3HAC035728-001 Revision: N
© Copyright 2009-2017 ABB. All rights reserved.
4 Repair
4.7.1 Replacing axis-1 motor with gearbox
Continued