Information
Action
xx1400002559
Secure the connectors to the plate with
cable ties.
11
Refit the attachment screws that secure the
cable plate, if removed.
12
Use caution and reconnect the battery cable
connector.
CAUTION
If too much force is used when the battery
cable is connected, there is a risk of dam-
aging the connector.
13
Tip
Leaving the attachment screws securing
the bracket with battery unscrewed, will
make it easier to connect the battery cable.
Secure the bracket with battery (if it has
been removed).
14
Make sure the earth cable is connected and
undamaged.
15
xx0900000836
Use caution and push in the plate with the
EIB board and battery into the base.
Note
Make sure that the cables are placed cor-
rectly and that no cables are damaged!
16
Parts:
•
A: Plate
•
B: Attachment screws M3x8 q12.8
(4 pcs)
Tightening torque: 2 Nm.
Secure the plate with its attachment screws.
17
Continues on next page
184
Product manual - IRB 120
3HAC035728-001 Revision: N
© Copyright 2009-2017 ABB. All rights reserved.
4 Repair
4.7.1 Replacing axis-1 motor with gearbox
Continued
Summary of Contents for IRB 120
Page 1: ...ROBOTICS Product manual IRB 120 ...
Page 8: ...This page is intentionally left blank ...
Page 90: ...This page is intentionally left blank ...
Page 114: ...This page is intentionally left blank ...
Page 224: ...This page is intentionally left blank ...
Page 250: ...This page is intentionally left blank ...
Page 254: ...This page is intentionally left blank ...
Page 264: ...This page is intentionally left blank ...
Page 270: ......
Page 271: ......