Note
Action
The FlexPendant will give all inform-
ation needed to proceed with Axis
Calibration.
Calibration method used at factory for each axis
is shown, as well as calibration method used for
the robot during last field calibration.
3
Tap
Run Calibration Method
. The software will
automatically call for the procedure for the valid
calibration method.
xx1500000944
A brief overview of the sequence
that will be run on the FlexPendant
is given in
tion procedure on the FlexPendant
on page 237
Follow the instructions given on the FlexPendant.
4
Restarting an interrupted calibration procedure
If the Axis Calibration procedure is interrupted before the calibration is finished,
the RobotWare program needs to be started again. Use this procedure to take
required action.
Action
Situation
Press and hold the three-position enabling
device and press
Play
.
The three-position enabling device on the
FlexPendant has been released during robot
movement.
Remove the calibration tool, if it is installed,
and restart the calibration procedure from
the beginning. See
.
The RobotWare program is terminated with
PP to Main
.
If the calibration tool is in contact the robot
axis needs to be jogged in order to release
the calibration tool. Jogging the axis in wrong
direction will cause the calibration tool to
break. Directions of axis movement is shown
in
Calibration movement directions for all
After calibration
Note
Action
Check that all dampers are refitted on axes 1, 2
and 3.
1
Continues on next page
240
Product manual - IRB 120
3HAC035728-001 Revision: N
© Copyright 2009-2017 ABB. All rights reserved.
5 Calibration
5.4.2 Axis Calibration - Running the calibration procedure
Continued
Summary of Contents for IRB 120
Page 1: ...ROBOTICS Product manual IRB 120 ...
Page 8: ...This page is intentionally left blank ...
Page 90: ...This page is intentionally left blank ...
Page 114: ...This page is intentionally left blank ...
Page 224: ...This page is intentionally left blank ...
Page 250: ...This page is intentionally left blank ...
Page 254: ...This page is intentionally left blank ...
Page 264: ...This page is intentionally left blank ...
Page 270: ......
Page 271: ......