HVC 450 kW E-Bus Charger Installation Guide
Revision: 1.2
COMPANY CONFIDENTIAL
Date released: 16-08-2018
Page
77
of
128
5.8.4. Connect the CAN cable
CAN cable connection in
slave 2
HVC 150S
:
A
Terminal block
B
CAN cable to slave 1 HVC 150S
1. Move the cable towards the terminal block (A).
2. Strip 0.43 Inch of the insulation from the ends of the wires.
3. Crimp a ferrule onto the end of the wire.
4. Loosen the connector screws.
5. Insert the wires into the connectors, see table below:
Functional description
Connector
Wire color
CAN H Out
X286-10
Brown
CAN L Out
X286-11
White
CAN GND
X286-12 or Shield Can Out
Shield
See also Appendix H
Signal connection diagram
.
6.
Tighten the connector screws.