Setting of the current meter
Refer to the SIMPSON H345 Digital controller operator’s manual (
).
Relay N°1 should be set to alarm (disconnected) when current is higher than 0.04 A and relay
N°2 should be set to alarm (disconnected) when current is lower than 0.022 A.
10.
Enter the rated frequency specified on the motor nameplate.
Press the
key to select the next parameter.
C04* Hz
MOT.RATED FREQ1
50.000
11.
Enter the rated power supply voltage.
C05* V
RATED MAINS
VLTG
400.000
12.
Set “NO RESPONSE”.
Press the
key to select the next parameter.
835* RESP. TF-SIG.
NO RESPONSE
DISPLAY ERROR
13.
Start the calculation for the startup data by choosing “YES”.
The process lasts a few seconds.
C06*CALCULATION
NO
YES
14.
The calculation is performed. After calculation, the next
menu item appears automatically.
C06*SAVE
NO
YES
15.
Set “SAVE” to “YES” The data (motor parameters) are copied
to the non-volatile memory of Movidrive.
STARTUP DATA IS
BEING COPIED
16.
The startup procedure is now complete. Press the
key to
return to the context menu.
MANUAL MODE
STARTUP
COPY TO DBG
COPY TO MDX
17.
Press the
keys to scroll down to the “QUIT” menu item.
SIGNATURE
QUIT
BASIC VIEW
18.
Confirm the setting by pressing the
key. The basic
display appears.
0.00rpm
0.000Amp
CONTROLLER
INHIBIT
Steps Action
Parameters
Summary of Contents for Feather Duster
Page 1: ...Product manual Feather Duster ...
Page 2: ......
Page 12: ...3HAW050027150 Revision C 10 Copyright 2013 1016 ABB All rights reserved ...
Page 92: ... Copyright 2013 1016 ABB All rights reserved ...
Page 100: ... Copyright 2013 1016 ABB All rights reserved ...
Page 110: ......
Page 148: ... Copyright 2013 1016 ABB All rights reserved ...
Page 149: ......