Introduction to the manual 27
Frame (size)
Refers to converter modules that share a similar mechanical construction, for
example:
• frame 5×R9iLC + 6×R9iLC includes five R9iLC generator-side converter
modules and six R9iLC grid-side converter modules.
Generator-side
converter
The converter part that is connected to the generator stator and controls the
generator operation. It converts the AC power from the generator to the
converter DC bus.
Grid-side converter
A converter that is connected to the grid and is capable of transferring energy
from the converter DC link to the grid and vice versa.
I/O
Input/Output
IGBT
Insulated gate bipolar transistor; a voltage-controlled semiconductor type widely
used in various converters because of their easy controllability and high
switching frequency.
Intermediate circuit
.
LCL filter
Inductor-capacitor-inductor filter at AC side of the grid-side converter.
Attenuates harmonics.
Main circuit breaker
Electrically-controlled main switching and protecting device. A withdrawable
breaker can also be used as the main disconnector.
MBC
Main breaker cubicle containing main switching and disconnecting devices,
power terminals, etc.
NETA-21
Remote monitoring tool
Parameter
User-adjustable operation instruction to the converter, or signal measured or
calculated by the converter.
PE
Protective Earth
PLC
Programmable logic controller
PSL
Power stage link
PROFIBUS®,
PROFIBUS DP,
PROFINET IO
Registered trademarks of PI - PROFIBUS & PROFINET International
R9iLC
UPS
Uninterruptible power supply
Wind turbine converter
A converter for controlling AC generators in wind turbine applications.
Wind turbine system
Wind turbine system consists of the wind turbine, wind turbine converter,
generator etc.
WTC
Wind turbine controller. The wind turbine controller controls the whole wind
turbine system.
ZMU
Memory unit attached to the BCU control unit connector X205 MEMORY UNIT.
Term/abbreviation
Explanation
Summary of Contents for ACS880-87LC-4000A/4021A-7
Page 4: ......
Page 10: ...10 ...
Page 17: ...Safety instructions 17 1 3 2 4 5 6 7 ...
Page 18: ...18 Safety instructions 8 9 ...
Page 28: ...28 Introduction to the manual ...
Page 52: ...52 Mechanical installation ...
Page 66: ...66 Planning the electrical installation ...
Page 74: ...74 Electrical installation Diagrams for the customer connections are presented below ...
Page 75: ...Electrical installation 75 optional Fast shutdown ...
Page 85: ...Maintenance 85 b c a Air flow direction 2 3 4 6 ...
Page 87: ...Maintenance 87 2 5 4 ...
Page 88: ...88 Maintenance 7 Arrow indicating the air flow direction 5 6 6 ...
Page 90: ...90 Maintenance Air flow circulation b a ...
Page 106: ...106 Maintenance ...
Page 124: ...124 Control units of the converter ...
Page 126: ...126 Dimension drawings ...
Page 127: ...Dimension drawings 127 ...
Page 128: ...128 Dimension drawings ...
Page 142: ...142 Cooling and heating ...