VX = Kit specifically designed for the Rittal VX25 enclosure system. Many kits without
this designation are also used with the VX25 system.
DC/DC converter modules
Converter units consisting of frame R8i converter modules are to be ordered as separate
modules. For converter unit ratings, see the technical data.
Modules used
DC/DC converter unit
Ordering code
(for options, see below)
Qty
Frame size
Type
U
N
= 690 V
ACS880-104LC-0480A-7+E205
1
R8i
ACS880-1604LC-0400A-7
ACS880-104LC-0530A-7+E205
1
R8i
ACS880-1604LC-0500A-7
ACS880-104LC-0600A-7+E205
1
R8i
ACS880-1604LC-0600A-7
ACS880-104LC-0670A-7+E205
1
R8i
ACS880-1604LC-0700A-7
ACS880-104LC-0750A-7+E205
1
R8i
ACS880-1604LC-0800A-7
ACS880-104LC-0850A-7+E205
1
R8i
ACS880-1604LC-0900A-7
ACS880-104LC-0530A-7+E205
2
2×R8i
ACS880-1604LC-1000A-7
ACS880-104LC-0600A-7+E205
2
2×R8i
ACS880-1604LC-1200A-7
ACS880-104LC-0670A-7+E205
2
2×R8i
ACS880-1604LC-1400A-7
ACS880-104LC-0750A-7+E205
2
2×R8i
ACS880-1604LC-1600A-7
ACS880-104LC-0850A-7+E205
2
2×R8i
ACS880-1604LC-1800A-7
Option codes
Ordering code format
+E205
: Internal du/dt filtering. Standard with 690 V modules. (When
the module is used as a DC/DC converter, it must always be ordered
with +E205.)
[Module type] + code [+code] …
For example,
ACS880-104LC-0480A-7 +E205
Note:
The energy storage does not belong to the ACS880 module product offering. The customer
must equip the DC/DC converter with a suitable energy storage system. For more information,
see
Selecting the energy storage (page 54)
Ordering information 93
Summary of Contents for ACS880-1604LC
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 1604LC DC DC converter modules Hardware manual ...
Page 2: ......
Page 4: ......
Page 12: ...12 ...
Page 16: ...16 ...
Page 34: ...34 ...
Page 42: ...Kits for ACS880 1604LC R8i unit in Rittal VX25 cabinets 42 Cabinet construction ...
Page 43: ...Stage 1 Installation of common parts Cabinet construction 43 10 ...
Page 45: ...Stage 3 Module installation parts Cabinet construction 45 10 ...
Page 46: ...Stage 4 DDC and energy storage connection 46 Cabinet construction ...
Page 47: ...Stage 5A DC connection with charging Cabinet construction 47 10 ...
Page 48: ...Stage 5B DC connection without charging 48 Cabinet construction ...
Page 49: ...Stage 6 Cooling components Cabinet construction 49 10 ...
Page 50: ...Stage 7 DDC module and filter installation 50 Cabinet construction ...
Page 51: ...Stage 8 Swing frame and shroud installation Cabinet construction 51 10 ...
Page 58: ...58 ...
Page 72: ...72 ...
Page 124: ...124 ...
Page 138: ...138 ...
Page 148: ...148 ...
Page 150: ...R8i DC DC converter module 150 Dimension drawings ...
Page 151: ...BDCL filter module Dimension drawings 151 ...
Page 152: ...Quick connector 152 Dimension drawings ...
Page 153: ...BCU control unit Dimension drawings 153 ...
Page 154: ...BAMU voltage current measurement unit Dimensions in mm 1 mm 0 0394 in 154 Dimension drawings ...