Connector pitch 5 mm, wire size 2.5 mm
2
Analog inputs AI1 and AI2
(XAI:4 … XAI:7).
Current input: –20…20 mA,
R
in
= 100 ohm
Current/voltage input mode selection by
switches
Voltage input: –10…10 V,
R
in
> 200 kohm
Differential inputs, common mode range ±30 V
Sampling interval per channel: 0.25 ms
Hardware filtering: 0.25 ms, adjustable digital filtering up to 8 ms
Resolution: 11 bit + sign bit
Inaccuracy: 1% of full scale range
Connector pitch 5 mm, wire size 2.5 mm
2
Analog outputs AO1 and AO2 (XAO)
0…20 mA,
R
load
< 500 ohm
Frequency range: 0…500 Hz
Resolution: 11 bit + sign bit
Inaccuracy: 2% of full scale range
Connector pitch 5 mm, wire size 2.5 mm
2
XD2D connector
Physical layer: RS-485
Termination by switch
Connector pitch 5 mm, wire size 2.5 mm
2
RS-485 connection (X485)
Physical layer: RS-485
Connector pitch 5 mm, wire size 2.5 mm
2
Safe torque off connection (XSTO)
Input voltage range: -3…30 V DC
Logic levels: “0” < 5 V, “1” > 17 V.
Note:
For the unit to start, both connections must be “1”. This applies
to all control units (including drive, inverter, supply, brake, DC/DC
converter etc. control units), but true Safe torque off functionality is
only achieved through the XSTO connector of the drive/inverter
control unit.
EMC (immunity) according to IEC 61326-3-1
Connector pitch 5 mm, wire size 2.5 mm
2
Safe torque off output (XSTO OUT)
To STO connector of inverter module.
Connector: RJ-45
Control panel connection (X13)
Cable length < 3 m
Connector: RJ-45
Ethernet connection (XETH)
This connection is not supported by the firmware.
Memory card type: SDHC
SDHC memory card slot (SD CARD)
Maximum memory size: 4 GB
The terminals of the control unit fulfill the Protective Extra Low Voltage (PELV) requirements. The PELV re-
quirements of a relay output are not fulfilled if a voltage higher than 48 V is connected to the relay output.
146 Control units of the drive
Summary of Contents for ACS880-1604LC
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 1604LC DC DC converter modules Hardware manual ...
Page 2: ......
Page 4: ......
Page 12: ...12 ...
Page 16: ...16 ...
Page 34: ...34 ...
Page 42: ...Kits for ACS880 1604LC R8i unit in Rittal VX25 cabinets 42 Cabinet construction ...
Page 43: ...Stage 1 Installation of common parts Cabinet construction 43 10 ...
Page 45: ...Stage 3 Module installation parts Cabinet construction 45 10 ...
Page 46: ...Stage 4 DDC and energy storage connection 46 Cabinet construction ...
Page 47: ...Stage 5A DC connection with charging Cabinet construction 47 10 ...
Page 48: ...Stage 5B DC connection without charging 48 Cabinet construction ...
Page 49: ...Stage 6 Cooling components Cabinet construction 49 10 ...
Page 50: ...Stage 7 DDC module and filter installation 50 Cabinet construction ...
Page 51: ...Stage 8 Swing frame and shroud installation Cabinet construction 51 10 ...
Page 58: ...58 ...
Page 72: ...72 ...
Page 124: ...124 ...
Page 138: ...138 ...
Page 148: ...148 ...
Page 150: ...R8i DC DC converter module 150 Dimension drawings ...
Page 151: ...BDCL filter module Dimension drawings 151 ...
Page 152: ...Quick connector 152 Dimension drawings ...
Page 153: ...BCU control unit Dimension drawings 153 ...
Page 154: ...BAMU voltage current measurement unit Dimensions in mm 1 mm 0 0394 in 154 Dimension drawings ...