Electrical installation
96
Connection procedure
WARNING!
Follow the instructions in chapter
. Ignoring the
instructions can cause physical injury or death, or damage to the equipment.
1. Disconnect the inverter cubicle from the DC supply (open the DC switch or
remove the fuses). Ensure by measuring that the drive is dead.
2. Open the door of the inverter module cubicle: Unlock the handle, release it from
the holder and turn upwards to release the door locking mechanism.
3. Remove the shroud that protects the output busbars and cable entries.
4. Remove the cooling fans. See
Replacing the inverter module fans (2×R8i and up)
on page
5. Lead the cables into the inside of the cubicle. For minimum radio frequency
interference and motor bearing current, ground the cable shield 360° at the lead-
through.
6. Connect the cables as follows:
- Cut the cables to suitable length. Strip the cables and conductors. Fasten the
cable lugs to the conductor ends.
- Twist the cable shields into bundles and connect to cabinet ground busbar.
- Connect the phase conductors to the output terminals. See the appropriate
connection diagram above.
- Tighten the phase conductors and PE to 70 N·m (50 lbf·ft).
7. Refit the fans.
8. Refit the shroud removed earlier and close the door.
9. Connect the motor end of the cable (see the diagrams above). For minimum radio
frequency interference and motor bearing current ground the cable shield 360° at
the lead-through of the motor terminal box, or ground the cable by twisting the
bare shield so that its width, when flattened, is at least 1/5 times its length (see
the drawing below). For motor-specific instructions, see its documentation.
Summary of Contents for ACS800-17LC
Page 1: ...ABB industrial drives Hardware manual ACS800 17LC Drives 55 to 5200 kW ...
Page 4: ......
Page 10: ...Update notice 6 ...
Page 18: ...Table of contents 12 ...
Page 26: ...Safety instructions 20 ...
Page 32: ...Introduction to the manual 26 ...
Page 60: ...Hardware description 54 ...
Page 74: ...Mechanical installation 68 ...
Page 114: ...Electrical installation 108 ...
Page 142: ...Maintenance 136 ...
Page 150: ...Internal cooling circuit 144 ...
Page 179: ...Dimensions 173 Frame sizes R7i R7i and R8i R8i bottom entry exit ...
Page 180: ...Dimensions 174 Frame sizes R7i R7i and R8i R8i marine units C121 ...
Page 182: ...www abb com drives www abb com drivespartners Contact us 3AUA0000065339 Rev B EN 2016 06 07 ...