The ACS800-04/U4 and ACS800-04M
18
Type code
The type code contains information on the specifications and configuration of the
drive. The first digits from left express the basic configuration (e.g. ACS800-04-
0170-5). The optional selections are given thereafter, separated by plus signs (e.g.
+E202). The main selections are described below. Not all selections are available for
all types. For more information, refer to
ACS800 Ordering Information
(EN code:
64556568, available on request).
Type code for ACS800-04 and ACS800-U4 pre-assembled units
Selection
Alternatives
Product series
ACS800 product series
Type
04
Drive module. When no options are selected: 6-pulse diode input bridge, IP 00, top
entry, side exit, RDCU drive control unit, no control panel, no EMC filter, Standard
Control Program, boards without coating, pedestal with output on the long side, output
busbar set for motor, base and wall mounting brackets, one set of manuals. Pre-
assembled unit.
U4
Drive module (USA). When no options are selected: 6-pulse diode bridge, open
chassis, top entry, side exit, no control panel, no EMC filter, US version of the
Standard Control Program (three-wire start/stop as default setting), common mode
filter in frame size R8, boards without coating, pedestal with output on the long side,
output busbar set for motor, base and wall mounting brackets, one set of manuals.
Pre-assembled unit.
Size
Refer to
Technical data: IEC ratings
or
NEMA ratings
in
Hardware Manual
[3AFE64671006
(English)].
Voltage range
(nominal rating in bold)
2 208/220/
230
/240 VAC
3
380/
400
/415 VAC
5
380/400/415/440/460/480/
500
VAC
7
525/575/600/
690
VAC
+ options
Resistor braking
D150 brake chopper and busbars for brake resistor and DC connection
Filter
E210
EMC/RFI filter for second environment TN/IT (grounded/ungrounded) system
E208
common mode filter
Pedestal and output
busbars
0H354 no pedestal
Control panel
J400
control panel including a 3-metre panel connection cable
J410
RPMP-11 control panel mounting platform kit including a 3-metre panel connection
cable but no control panel
J413
RPMP-21 control panel holder
Fieldbus
K...
Refer to
ACS800 Ordering Information
(EN code: 64556568).
I/O
L...
Control program
N...
Language of manual
R...
Specialities
P901
coated boards
Safety features
Q950 Prevention of Unexpected Start, 500 mm (19.68 in.) cable outside the drive module in
frame size R7, 600 mm (23.62 in.) cable outside the drive module in frame size R8.
Summary of Contents for ACS 800 Series
Page 4: ......
Page 10: ...Table of contents 10...
Page 119: ...Dimensional drawings 119 Dimensional drawings...
Page 120: ...Dimensional drawings 120 Frame size R7 without pedestal mm 64796003_3 7 E Center of gravity...
Page 121: ...Dimensional drawings 121 Frame size R7 with bottom exit mm 64796003_6 7 G...
Page 123: ...Dimensional drawings 123 Frame size R7 with busbars on the left side mm 64796003_5 7 G...
Page 127: ...Dimensional drawings 127 Frame size R8 without pedestal mm 64801082_3 6 E Center of gravity...
Page 128: ...Dimensional drawings 128 Frame size R8 with busbars on the left side mm 64801082_5 6 E...
Page 136: ...Dimensional drawings 136 Control Panel Holder RPMP 21 J413 64770306_20 20 E...
Page 138: ...Dimensional drawings 138 Dimensional drawings USA...
Page 140: ...Dimensional drawings 140 Frame size R7 with bottom exit inches 68439221_6 7 F F F...
Page 142: ...Dimensional drawings 142 Frame size R7 with busbars on the left side inches 68439221_5 7 F...
Page 152: ...Dimensional drawings 152...
Page 160: ...Assembly drawings 160...
Page 161: ......