en07000113-1.vsd
L1
L2
L3
1
2
3
4
5
6
9
10
1
2
3
4
5
6
9
10
I1
I2
I3
I5
I1
I2
I3
I5
IEC07000113 V2 EN-US
Figure 104:
Example of connection of parallel line IN for Fault locator
LMBRFLO
10.9
Limit counter L4UFCNT
GUID-22E141DB-38B3-462C-B031-73F7466DD135 v1
10.9.1
Identification
GUID-F3FB7B33-B189-4819-A1F0-8AC7762E9B7E v2
Function description
IEC 61850
identification
IEC 60617
identification
ANSI/IEEE C37.2
device number
Limit counter
L4UFCNT
-
10.9.2
Application
GUID-41B13135-5069-4A5A-86CE-B7DBE9CFEF38 v2
Limit counter (L4UFCNT) is intended for applications where positive and/or
negative flanks on a binary signal need to be counted.
The limit counter provides four independent limits to be checked against the
accumulated counted value. The four limit reach indication outputs can be utilized
Section 10
1MRK 511 423-UEN A
Monitoring
222
Bay control REC650 2.2 IEC
Application manual