Program Interface Library
AR_DEFINE_MSG
CEI-100/CEI-200/CEI-
x20 User’s Manual
74
You can change the scheduled mode label that responds to the SIGNAL by
calling AR_MODIFY_MSG () with the new “msg_num” and a negative
“rate”.
ARS_INVBOARD
The specified board is a CEI-100.
(Supported by the CEI-200/x20 only).
ARS_BRDNOTLOAD
Board not loaded and initialized.
ARS_INVARG
Scheduled transmission mode has not
been previously selected or an invalid
channel was specified or the maximum
number of messages has already been
defined.
ARS_BOARD_MUTEX
Failed to acquire/release the board lock.
message_num
A return value in the range 0-47 (0-119
for the CEI-x20) indicates success and is
the unique message number assigned to
this message. Each channel assigns
message numbers in this range.
board
(input) board number of interest.
channel
(input) transmit channel of interest.
rate
(input) re-transmission rate of the message in clock
ticks.
start
(input) initial delay (in ticks) from the current time
until the message is transmitted for the first time.
Subsequent transmissions of this data are at the rate
defined in the previous argument. If you wish to
schedule multiple labels for transmission at intervals
that are relative to each other, I recommend that you
stop all board processing with AR_RESET(), define
the messages, then resume ARINC label processing
by calling AR_GO().
data
(input) ARINC data to transmit, which must be
reformatted into the same bit order as required by
AR_PUTWORD.
Return Value
Arguments
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com