15
RQ Series Feature String Nomenclature
:
V
L
T
C
O
N
F
IG
A1
A2
A3
A4
B1
B2
B3
1A
1B
1C
1D
2
3
4
5A
5B
5C
6A
6B
6C
7
8
9
10
11
12
13
14A
14B
15
16
17
18
19
20
21
22
23
R Q - 0 0 5 - 3 - V - B B 0 1 - 3 3 4 :
A 0 0 0
-
D 0
B - P J C - 0 B A - 0 D 0 0 0 0 L - 0 0 - 0 0 B 0 0 0 0 0 B
Model Options
Unit Feature Options
G
E
N
S
IZ
E
Feature 1: RETURN/OUTSIDE AIR
1A: RETURN/OUTSIDE AIR SECTION
0 = Manually Adjustable OA O RA Opening
A = Economizer
B = Econ + Power Exhaust
F = Low cfm Total Energy Recovery Wheel
G = Low cfm Total ERW + Bypass Damper
H = Low cfm Sensible ERW
J = Low cfm Sensible ERW + Bypass Damper
K = 100% Outside Air - No Return Air Opening
L = Motorized Outside Air RA Opening
M = Motorized Outside Air Damper - No RA
Opening
N = Empty ERW Option Box- No Power Exhaust
P = Empty ERW Option Box + Power Exhaust
Q = Low cfm Total Fixed Plate Energy Recovery
R = Low cfm Total Fixed Plate Energy Re
Bypass Damper
S = Low cfm Sensible Fixed Plate Energy Recovery
T = Low cfm Sensible Fixed Plate Energy Recovery
+ Bypass Damper
U = High cfm Total Fixed Plate Energy Recovery
V = High cfm Total Fixed Plate Energy Re
Bypass Damper
W = High cfm Sensible Fixed Plate Energy Recovery
Y = High cfm Sensible Fixed Plate Energy Recovery
+ Bypass Damper
5 = 100% Return Air
1B: RETURN/EXHAUST AIR BLOWER
CONFIGURATION
0 = Standard – None
A = 1 Standard Eff. Motor
C = 1 Premium Eff. Motor
E = 1 Premium Eff. Motor + 1 VFD
H = 1 High Efficiency EC Motor
J = 1 Single Phase Motor + Speed Control
K = Option E + Shaft Grounding
1C: RETURN/EXHAUST AIR BLOWER
0 = Standard - None
B = 15” Backward Curved Plenum
C = 18.5” Backward Curved Plenum
J = 15” Backward Curved Plenum - 70% Width
K = 18.5” Backward Curved Plenum - 60% Width
N= 16” Axial Flow
1D: RETURN/EXHAUST AIR BLOWER
MOTOR
0 = Standard - None
A = 0.25 hp - 850 rpm
B = 0.5 hp - 1075 rpm
C = 1 hp - 1750 rpm
D = 2 hp - 1760 rpm
W = 0.75 hp - 1760 rpm
Z = 0.167 hp - 825 rpm
Feature 2: OUTSIDE AIR CONTROL
0 = Standard - None
A = 3 Position Actuator - Sensible Limit
B = 3 Position Actuator - Enthalpy Limit
C = Fully Modulating Actuator - Sensible Limit
D = Fully Modulating Actuator - Enthalpy Limit
E = DDC Actuator
M = 3 Pos. Act. - Sensible Limit + CO
2
Override
N = 3 Pos. Act. - Enthalpy Limit + CO
2
Override
P = Fully Mod. Act. - Se CO
2
Override
Q = Fully Mod. Act. - En CO
2
Override
R = DDC Ac CO
2
Override
S = Dual Minimum Position Potentio Fully
Mod. Act. - Sensible Limit
T = Dual Minimum Position Potentio Fully
Mod. Act. - Enthalpy Limit
U = 2 Position Actuator
Y = Fault Detection and Diagnostics Controller
(FDD) - Sensible Limit
Z = FDD - Enthalpy Limit
1 = FDD Sensible Chan CO2 Override
2 = FDD Enthalpy Chan CO2 Override
Feature 3: HEAT OPTIONS
0 = Standard - None
E = Discharge Air Override
K = Auxiliary Heat K
L = Auxiliary Heat L
M = Auxiliary Heat M
N = Auxiliary Heat N
Summary of Contents for RQ SERIES
Page 2: ......
Page 29: ...29 Figure 3 RQ Cabinet Standard and Power Exhaust Gasket Locations ...
Page 43: ...43 Figure 21 Example 2 6 ton through the Base Gas Piping ...
Page 49: ...49 Figure 22 Post Corner Hole Location Figure 23 Post Back Hole Location ...
Page 50: ...50 Figure 24 Post Corner Hole Piping Figure 25 Post Back Hole Piping ...
Page 67: ...67 Gas Heater Instructions Figure 27 Gas Heater Instructions ...
Page 97: ......
Page 98: ......
Page 99: ......