HV/HW-CEP Series
11.
Comparator
Five-level, three-level and seven-level (portion weighing mode) comparators are
available.
Each comparator mode compares the weight value against the preset limit values and
displays the results using LEDs (yellow / green / red).
·
Five-level comparator mode:
Uses four comparator values to
compare the weight value and displays
results in five levels of LOLO, LO, OK,
HI and HIHI.
·
Three-level comparator mode:
Uses two comparator values (upper
and lower limit values) to compare the
weight value and displays results in
three levels of LO, OK and HI.
·
Seven-level comparator mode (portion weighing mode):
Uses six comparator values to compare
the weight value and displays results in
seven levels of over in the negative
value, level 1 (LOLO), level 2 (LO),
Level 3 (OK), level 4 (HI), level 5 (HIHI)
and over in the positive value.
To use the comparator modes, the function settings “
Cp-l
” and “
Cp
” must be
specified and the comparator values must be set.
Using the function setting “
Cp-l
”, select a comparator mode.
0
: five-level comparator mode
1
: three-level comparator mode
2
: Seven-level comparator mode (portion weighing mode)
Using the function setting “
Cp
”, select comparison conditions.
0
: No comparison (comparator mode disabled).
1
: To compare all data.
2
: To compare all stable data.
3
: To compare all data which are more than or equal to +5d, or less than
or equal to -5d.
4
: To compare stable data which are more than or equal to +5d, or less
than or equal to -5d.
5
: To compare all data which are more than or equal to +5d.
6
: To compare stable data which are more than or equal to +5d.
d = minimum display in kg (Refer to “15. Specifications”.)
Also in the counting mode, “d” is equal to the minimum display of kg mode.