16
T2300-T2350-T2400-T2450 Double Mitre Saw
Picture 4.3 A – minimum distances (expressed in mm) for the installation
A= Container of pieces still to be worked
B= Container of already worked pieces
To answer to the characteristics of accuracy and balance, the double mitre saws must be positioned on a compact
concrete foundation in reinforced cement.
The design and arrangement of such a foundation is charged to the customer.
Be sure that a.m. foundation is properly consolidated in order to avoid possible sagging at machine’s installation.
4.4 ASSEMBLY
The machine assembly is executed by the customer following the instructions listed here below:
• Remove by using a lever (i.e. a big screwdriver) the nails fastening the crate to the pallet
• Draw out the crate from the upper side.
• Draw out the transparent packaging from the upper side.
• Keep the external packing for a possible future re-utilization
• Screw the eyebolts in the 2 holes M12 located on machine’s top side
• Lift the machine using a lift truck and carry it on its spot.
4.5 POSITIONING
The machine must be positioned on the ground on its assigned area.
Summary of Contents for T2 Series
Page 3: ...3 Double Mitre Saw T2300 T2350 T2400 T2450...
Page 37: ...37 Double Mitre Saw T2300 T2350 T2400 T2450 ATTACHMENT A MACHINE OVERALL DIMENSIONS...
Page 38: ...38 T2300 T2350 T2400 T2450 Double Mitre Saw ATTACHMENT B MECHANIC SCHEMATICS PRELIMINARY...
Page 39: ...39 Double Mitre Saw T2300 T2350 T2400 T2450...
Page 40: ...40 T2300 T2350 T2400 T2450 Double Mitre Saw...
Page 41: ...41 Double Mitre Saw T2300 T2350 T2400 T2450...
Page 42: ...42 T2300 T2350 T2400 T2450 Double Mitre Saw...
Page 44: ...44 T2300 T2350 T2400 T2450 Double Mitre Saw ATTACHMENT D ELECTRIC SCHEMATICS...
Page 45: ...45 Double Mitre Saw T2300 T2350 T2400 T2450 ATTACHMENT E PLATES DISLOCATION PRELIMINARY...