7
Double Mitre Saw T2300-T2350-T2400 - T2450
2.5 SURROUNDING CONDITIONS
The machine does not need special surrounding conditions. It has to be installed inside an industrial building,
lit, aired and with a compact and flat floor. The admitted temperatures go from 5° to 40° C, with an humidity not
higher than 50% at 40° C or 90% at 20° C.
2.6 LIGHTING
Premises lighting must be conformed to the norms in force in that Country where the machine is installed and has
to guarantee a clear visibility, do not create dangerous reflections and allow a clear reading of the control panel
and the location of emergency button.
2.7 VIBRATIONS
In standard conditions conformed to the indication of machine proper utilization (the machine is anchored to the
ground by 4 fastening points), the vibrations do not create dangerous conditions.
The average quadratic weighed level, according to the acceleration frequency to which arms are exposed does
not exceed 2,5 m/s
2
.
2.8 NOISE EMISSIONS
The machine is designed and projected for reducing the noise emission level to its source. Tests have been effected
according to the measurement method conformed with Art. 46 D.Lgsl. 277/91.
The T2xxx Double Mitre Saw, when workings on standard and correct conditions of use, produces a sound level
per operator lower than 85 bB (A) even if used continuously.
For this survey has been considered the cut of hardwood type Ramin which can be used for manufacturing of
picture frames. The use of softer woods (i.e. Obeche) produces sound levels lower of about 2-3 dB (A).
The noise levels indicated are emission levels and are not representing sure operating levels. In spite of existing a
relationship among emission levels and exposure ones, this can not be used in a reliable way to define if further
cautions are necessary. The factors determining the exposure level to which the working force is subjected,
include exposure lasting, working premises characteristics and other noise sources (number of machines, closed
proceeds, etc…). Furthermore, also the allowed exposure levels could change according to the several Countries.
At any rate, the information provided, will allow the Machine Operator to achieve a better evaluation of danger
and risks he is submitted to.
The indicated noise levels are emission ones measured in standard conditions of use. In case of
any machine modification, the above mentioned levels could be changed and should be settled
directly on the same machine.
Use the machine only if equipped with special individual protections for hearing (headphones etc…).
2.9 TECHNICAL DATA
Here below are indicated Machine technical data and characteristics to which make reference for any eventual
contact with Producer Technical Assistance.
Summary of Contents for T2 Series
Page 3: ...3 Double Mitre Saw T2300 T2350 T2400 T2450...
Page 37: ...37 Double Mitre Saw T2300 T2350 T2400 T2450 ATTACHMENT A MACHINE OVERALL DIMENSIONS...
Page 38: ...38 T2300 T2350 T2400 T2450 Double Mitre Saw ATTACHMENT B MECHANIC SCHEMATICS PRELIMINARY...
Page 39: ...39 Double Mitre Saw T2300 T2350 T2400 T2450...
Page 40: ...40 T2300 T2350 T2400 T2450 Double Mitre Saw...
Page 41: ...41 Double Mitre Saw T2300 T2350 T2400 T2450...
Page 42: ...42 T2300 T2350 T2400 T2450 Double Mitre Saw...
Page 44: ...44 T2300 T2350 T2400 T2450 Double Mitre Saw ATTACHMENT D ELECTRIC SCHEMATICS...
Page 45: ...45 Double Mitre Saw T2300 T2350 T2400 T2450 ATTACHMENT E PLATES DISLOCATION PRELIMINARY...