34
T2300-T2350-T2400-T2450 Double Mitre Saw
TABLE 6.6 - A
SERVICE
DESCRIPTION
MACHINE STATE
Lubricate the blade descent guide
a) Lubricate columns (up and down
slides) with grease Molykote PG21
every 800-1000 hours
a) Isolation of the machine for
maintenance
Lubricator (only for machines with
cooling system)
a) Check the oil level. Seal with oil type
ENERGOL HP 10 or equivalent
a) Isolation of the machine for
maintenance
Pneumatic system
a) Cleaning the potion-regulator
lubricator every 30 days
b) Plugging the oil level in the lubricator
filter (*)
a) Isolation of the machine for
maintenance
b) Isolation of the machine for
maintenance
Electrical cabinet
a) Checking and tightening the cables
every 12 months
b) Checking and tightening the fuses
every 12 months)
a) Isolation of the machine for
maintenance
b) Isolation of the machine for
maintenance
Stop engines
a) Checking and adjustment and / or
possible replacement of the brake
pad all 150/200 hours
a) Isolation of the machine for
maintenance
Blades protective housing
a) Monthly control of the presence of
process waste cleaning and removing
those which are stuck
a) Isolation of the machine for
maintenance
Columns protective casing
a) Monthly check presence of scraps
and remove them
a) Isolation of the machine for
maintenance
(*) Use oil type ENERGOL HP10. Do not use oil for engines, brake fluid, gas oil or other products
to avoid irrevocable damages to the gaskets.
6.7 EXTRAORDINARY MAINTENANCE
Here below are listed the operations that need the intervention of A-Plus Automation Qualified Staff authorized
from the Manufacturer (see paragraph 1.2)
The extraordinary maintenance, includes interventions effected in case of exceptional events:
• Breakage
• Overhauling
• TABLE 6. 7 - A
SERVICE
DESCRIPTION
MACHINE STATE
Driving belt replacement
a) isolation for maintenance:
pneumatic cut-out switch opened
main switch on position “0”
Setting up of machine cutting geometry a) adjustment of motor supports ( re-
positioning of blades at 45°)
b) adjustment of verticality
a) isolation for maintenance:
pneumatic cut-out switch opened
main switch on position “0”»
Blades replacement
a) blades replacement for re-sharpening a) isolation for maintenance:
pneumatic cut-out switch opened
main switch on position “0”
Summary of Contents for T2 Series
Page 3: ...3 Double Mitre Saw T2300 T2350 T2400 T2450...
Page 37: ...37 Double Mitre Saw T2300 T2350 T2400 T2450 ATTACHMENT A MACHINE OVERALL DIMENSIONS...
Page 38: ...38 T2300 T2350 T2400 T2450 Double Mitre Saw ATTACHMENT B MECHANIC SCHEMATICS PRELIMINARY...
Page 39: ...39 Double Mitre Saw T2300 T2350 T2400 T2450...
Page 40: ...40 T2300 T2350 T2400 T2450 Double Mitre Saw...
Page 41: ...41 Double Mitre Saw T2300 T2350 T2400 T2450...
Page 42: ...42 T2300 T2350 T2400 T2450 Double Mitre Saw...
Page 44: ...44 T2300 T2350 T2400 T2450 Double Mitre Saw ATTACHMENT D ELECTRIC SCHEMATICS...
Page 45: ...45 Double Mitre Saw T2300 T2350 T2400 T2450 ATTACHMENT E PLATES DISLOCATION PRELIMINARY...