Size
Description
Unit
BFC 80
BFC 100
BFC 120
A
Overall height
mm
2060
2060
2060
C
Position on pallet
mm
530
530
530
D
Appliance diameter
mm
850
850
850
E
Depth
mm
1000
1000
1000
F
Width
mm
900
900
900
G
Diameter of flue gas
discharge
mm
130/200
130/200
130/200
H
Height of flue gas
outlet/air supply
mm
1995
1995
1995
Hx
x position flue gas
outlet
mm
310
310
310
Hy
x position flue gas
outlet
mm
440
440
440
K
Height of gas
connection
mm
1855
1855
1855
M
Height of cold water
supply
mm
225
225
225
N
Height of hot water
outlet
mm
2060
2060
2060
Ny
y position of hot water
outlet
mm
205
205
205
P
Height of cleaning
opening
mm
290
290
290
R
Height of drain valve
connection
mm
225
225
225
S
Height of T&P valve
connection
mm
1425
1425
1425
W
Height of condensation
drain
mm
240
240
240
1
Cold water supply
connection (external)
-
R 1
1
/
2
R 1
1
/
2
R 1
1
/
2
2
Hot water outlet
(male)
-
R 1
1
/
2
R 1
1
/
2
R 1
1
/
2
3
Gas control valve
connection (external)
-
R
3
/
4
"
R
3
/
4
"
R
3
/
4
"
4
Drain valve connection
(internal)
-
3
/
4
"
3
/
4
"
3
/
4
"
5
T&P valve connection
(female)
-
1"-11.5 NPT
1"-11.5 NPT
1"-11.5 NPT
6
Cleaning/inspection
opening
mm
95 x 70
95 x 70
95 x 70
7
Condensation drainage
connection (female)
-
Ø 40
Ø 40
Ø 40
0311704_BFC_28-120_III_
ENEN_V2.4, 2022-10-17
103
Summary of Contents for BFC Cyclone 120
Page 6: ...6 ...
Page 13: ...User part 0311704_BFC_28 120_III_ENEN_V2 4 2022 10 17 13 ...
Page 14: ...14 ...
Page 16: ...16 User part ...
Page 18: ...18 User part ...
Page 24: ...24 User part ...
Page 41: ...Installation Maintenance and Service part 0311704_BFC_28 120_III_ENEN_V2 4 2022 10 17 41 ...
Page 42: ...42 User part ...
Page 46: ...46 Installation Maintenance and Service part ...
Page 52: ...52 Installation Maintenance and Service part ...
Page 59: ...Fig Venting systems 0311704_BFC_28 120_III_ENEN_V2 4 2022 10 17 59 ...
Page 76: ...76 Installation Maintenance and Service part ...
Page 78: ...78 Installation Maintenance and Service part ...
Page 84: ...84 Installation Maintenance and Service part ...
Page 102: ...Fig Dimensions BFC 28 30 50 60 102 Installation Maintenance and Service part ...
Page 104: ...Fig Dimensions BFC 80 100 120 104 Installation Maintenance and Service part ...
Page 112: ...12 7 Declaration of conformity 112 Installation Maintenance and Service part ...
Page 113: ......
Page 114: ......
Page 118: ...116 Installation Maintenance and Service part ...