BFC 28 to 60
If necessary, adjust the CO
2
value using the adjuster screw until the value is within
the range listed in the table of CO
2
values.
Use the Allen key supplied for this. The key can be found in the plastic bag that is
attached to the appliance.
Fig. CO
2
adjustment (full load)
IMD-1095b R0
Note
Turning to the left (anticlockwise) means more gas (higher CO
2
level) and turning to the
right (clockwise) means less gas (lower CO
2
level).
Note
Note
After conversion, you must check that the gas control valve is gastight.
If you have increased T
set
, set it back to the original value using [ ].
Continue with the CO
2
measurement under partial load.
BFC 80 to 120
If the measure value is within the range given in the table of CO
2
values:
If you have increased T
set
, set it back to the original value using [ ].
Continue with the CO
2
measurement under partial load.
If the measured value is not within the range of CO
2
values from the table, then you
may not start the appliance up:
Switch off the appliance.
Turn off the gas supply to the appliance.
Put the covers back on the appliance.
Contact the appliance's supplier.
Partial load measurement
From the service menu, select:
SERVICE OPERATION | PARTIAL LOAD
Confirm with [ENTER].
The appliance is now in PARTIAL LOAD mode and will ignite
The appliance is now running at PARTIAL LOAD. Read the value from the CO
2
meter
and wait until this measured value has remained stable for some time. This may take
several minutes.
13.
n
14.
15.
16.
-
-
17.
-
-
-
18.
19.
-
-
20.
72
Installation, Maintenance and Service part
Summary of Contents for BFC Cyclone 120
Page 6: ...6 ...
Page 13: ...User part 0311704_BFC_28 120_III_ENEN_V2 4 2022 10 17 13 ...
Page 14: ...14 ...
Page 16: ...16 User part ...
Page 18: ...18 User part ...
Page 24: ...24 User part ...
Page 41: ...Installation Maintenance and Service part 0311704_BFC_28 120_III_ENEN_V2 4 2022 10 17 41 ...
Page 42: ...42 User part ...
Page 46: ...46 Installation Maintenance and Service part ...
Page 52: ...52 Installation Maintenance and Service part ...
Page 59: ...Fig Venting systems 0311704_BFC_28 120_III_ENEN_V2 4 2022 10 17 59 ...
Page 76: ...76 Installation Maintenance and Service part ...
Page 78: ...78 Installation Maintenance and Service part ...
Page 84: ...84 Installation Maintenance and Service part ...
Page 102: ...Fig Dimensions BFC 28 30 50 60 102 Installation Maintenance and Service part ...
Page 104: ...Fig Dimensions BFC 80 100 120 104 Installation Maintenance and Service part ...
Page 112: ...12 7 Declaration of conformity 112 Installation Maintenance and Service part ...
Page 113: ......
Page 114: ......
Page 118: ...116 Installation Maintenance and Service part ...