Switch the water heater OFF (position 0) using the control switch on the operator
interface.
Isolate the water heater from the power supply by setting the isolator between the
water heater and the mains power supply to position 0.
Shut off the gas supply (10).
Close the stop valve (11) in the hot water pipe.
Close the supply valve (4) in the cold water inlet (A).
Open the drain valve (9).
7.9.2.2
Draining vented installations
Some service activities require the water heater to be drained. The procedure is as
follows:
Activate the MENU with [
].
Position the cursor in front of OFF.
Confirm OFF with [ENTER].
Wait until the fan has stopped. The icon is then dimmed.
Caution
Failure to wait until the fan stops can cause damage to the water heater.
Switch the water heater OFF (position 0) using the control switch on the operator
interface.
Isolate the water heater from the power supply by setting the isolator between the
water heater and the mains power supply to position 0.
Shut off the gas supply (10).
Close the stop valve (11) in the hot water pipe.
Close the stop valve (4) between the cold water head tank and the cold water inlet
(A).
Open the drain valve (9).
Bleed the water heater (or installation) so that it drains completely.
5.
6.
7.
8.
9.
10.
1.
2.
3.
4.
c
5.
6.
7.
8.
9.
10.
11.
0311704_BFC_28-120_III_
ENEN_V2.4, 2022-10-17
75
Summary of Contents for BFC Cyclone 120
Page 6: ...6 ...
Page 13: ...User part 0311704_BFC_28 120_III_ENEN_V2 4 2022 10 17 13 ...
Page 14: ...14 ...
Page 16: ...16 User part ...
Page 18: ...18 User part ...
Page 24: ...24 User part ...
Page 41: ...Installation Maintenance and Service part 0311704_BFC_28 120_III_ENEN_V2 4 2022 10 17 41 ...
Page 42: ...42 User part ...
Page 46: ...46 Installation Maintenance and Service part ...
Page 52: ...52 Installation Maintenance and Service part ...
Page 59: ...Fig Venting systems 0311704_BFC_28 120_III_ENEN_V2 4 2022 10 17 59 ...
Page 76: ...76 Installation Maintenance and Service part ...
Page 78: ...78 Installation Maintenance and Service part ...
Page 84: ...84 Installation Maintenance and Service part ...
Page 102: ...Fig Dimensions BFC 28 30 50 60 102 Installation Maintenance and Service part ...
Page 104: ...Fig Dimensions BFC 80 100 120 104 Installation Maintenance and Service part ...
Page 112: ...12 7 Declaration of conformity 112 Installation Maintenance and Service part ...
Page 113: ......
Page 114: ......
Page 118: ...116 Installation Maintenance and Service part ...