Error! Use the Start tab to apply “Title 1” to the text need to be displayed here.
18
3.6.4.
Tool number setting of the bamboo hat type tool magazine
Function Path: Maintenance Group > User Parameters > Project Parameters
1.
Set the user parameter first 9005: the bamboo hat type tool magazine sets the origin spindle tool
number, 9006: the bamboo hat type tool magazine sets the origin standby tool number.
2.
In the origin mode, I407 is triggered: the tool number corrects the input signal.
3.
The system will immediately set the spindle tool number and the standby tool number to the
parameters and set values.
Backup
3.7.
Function Path: Maintenance Group > Backup
1.
Use U-disk for system backup and restore actions:
i.
Backup: After inserting the USB flash drive, check
the export to USB
, select
all data backup
,
press the
transfer
and select the U-disk folder. After selecting it, press
OK
to start the backup
and wait for a few seconds until the system prompts the transfer to complete. After the backup
is completed, the backup folder will appear, and the files inside will be the backup files.
ii.
Restore: After inserting the USB-disk, check the
USB import
, select
the upper layer
folder
where the backup folder is placed in the USB-disk, and press the
transfer
to start restoring the
system data after the selection. After the restoring is complete, you must restart the system to
restore the original backup state.
2.
Note
:
This feature must be performed after an emergency stop has been pressed to prevent the
machine from unpredictable conditions during the backup process.
System Update
3.8.
Feature Path: Maintenance Group > System Update