5. AUTOMATIC CLOSING CONDITION SETTING
a. Press and hold the
SET
Button until “1” appears on the
display, next press the
UP
button until “5” appears on
the display to enter this function setting then release the
button.
b. Press the
SET
button again. The unit is now in automatic
close condition adjustment mode. And then you will see
a figure “1” with flash dot appears on the display.
c. Press
UP / Down
button once to set the auto close
condition. You can choose “1” or “2” set.
Figure “1” means, the door only can auto close while in
the open limit position.
Figure “2” means, the door can auto close while the
door is in any position.
d. Press the
SET
button to confirm the set and it will back
to standby status automatically and display “ll”.
NOTE
:
• 1. The closing condition is set on “1” as standard in
factory.
• The door will only automatic close while in its opening
process, but can’t automatic close after it is stopped
while in its closing process.