Operator 

I

nstallation and 

I

nstructions for the 

Eagle-2000 and Eagle-1000 Series.

Sliding Gate

 

 

    Eagle-2000 Series

 

 

    Eagle-1000 Series

UL325 and UL991 Compliant

Summary of Contents for Eagle-1000 series

Page 1: ...ibuted by AFW Access Systems Phone 305 691 7711 www AnchorMiami com Operator Installation and Instructions for the Eagle 2000 and Eagle 1000 Series Sliding Gate Eagle 2000 Series Eagle 1000 Series UL3...

Page 2: ...Switches Emergency Releases Mounting the Secondary Entrapments Resetting the Motor Control Board LED Indicators Troubleshooting Parts Breakdown Eagle 2000 Parts Breakdown Eagle 1000 Operator Parts Li...

Page 3: ...horized use 6 All warning signs and placards must be installed where visible in the area of the gate 7 For a gate operator utilizing a non contact sensor such as a photo beam See instructions on the p...

Page 4: ...entrance or exit to a drive parking lot or the like UL Listings __________________________________________ Gate A moving barrier such as a swinging sliding raising lowering rolling or like barrier tha...

Page 5: ...ble for any improper installation procedures caused by installer or user failing to comply with local building codes CAUTION ____________________ Precautions Be sure to mount ALL operating devices cle...

Page 6: ...ost with a minimal distance of 4 Four inches between the rollers as shown in Example B Also when fully open the end of the sliding gate must stop at least 3 three inches from any wall or other objects...

Page 7: ...Front Installation Rear Installation ____________________ Proper Chain Installation Minimum space between gate and output sprocket must be 4 After you position the gate operator bolt down the operato...

Page 8: ...mendations are installation suggestions only Please consult local codes for actual requirements in your area Note ____________________ Selecting Opening Direction of Gate Distributed by AFW Access Sys...

Page 9: ..._ Reverse Exit Loop Installation The purpose of a reversing loop is to prevent the gate from closing on a vehicle while it is exiting or stopped in the middle of the gate area The purpose of the exit...

Page 10: ...r closing the gate There is an LED OVERLOAD warning that will light up when the gate is heavier than normal for the operator During this warning the operator will not function properly Too Sensitive i...

Page 11: ...uphill downhill applications and on all Fail Safe operators Distributed by AFW Access Systems www AnchorMiami com afwas 11 Slide Gate Operators Eagle 2000 Series Eagle 1000 Series ___________________...

Page 12: ...r to work as a three button station and is useful for a partial opening If selected the first command will open the gate the second will stop the gate and the third will close the gate Switch 7 Alarm...

Page 13: ...ributed by AFW Access Systems www AnchorMiami com afwas 13 Important Be sure that the 120VAC power for the Master and the Slave are connected to the same circuit breaker Master and Slave Operation ___...

Page 14: ...Selecting the switch to the on position delays the Slave Sw 5 or Master Sw 6 operator by 1 1 2 seconds on the open cycle This is useful with magnetic lock applications Setting The Close Delay Function...

Page 15: ...rovides 24 VAC Power which can be used for loop detectors and receivers Distributed by AFW Access Systems www AnchorMiami com afwas 15 Safety Alarm If the gate hits an obstruction twice while closing...

Page 16: ...the exeption of the MAG Lock all of these accessories can be installed on the Master or Slave operator Distributed by AFW Access Systems www AnchorMiami com afwas 16 Reverse Loop Phantom Loop Exit Loo...

Page 17: ...hile the gate is open will disable the timer to close function from automatically closing the gate Edge Sensor Momentary or Continuous Signal This signal is active when the gate is opening and or clos...

Page 18: ...tches 4 Wire Connections 3 Wire Connections The receiver terminal is mounted on the control box for easy installation and is pre wired for a 3 wire or 4 wire receiver ____________________ Adjust cams...

Page 19: ...drill ____________________ The Fail Safe System Optional Release Procedure Using the Eagle 2070 Fire Box 1 2 3 ____________________ Distributed by AFW Access Systems www AnchorMiami com afwas 19 Pull...

Page 20: ...on is available for resetting the motor If operator ceases to function then simply locate the reset button press and then turn the power back on ____________________ EMERSO MOTOR LEESON MOTOR Edge Sen...

Page 21: ...4 5 6 7 9 11 12 13 14 15 16 17 Distributed by AFW Access Systems www AnchorMiami com afwas 21 10 1 Power On 5 Key Keypad 10 Receiver 15 Overload 2 Master Slave 6 Stop 11 Close Limit 16 Active Communic...

Page 22: ...on position B Check any Global Inputs for a possible short circuit C Only key keypad and receiver will resume normal operation D Reset Loop Detector verify correct wiring set to a differ ent frequenc...

Page 23: ...ystem Model 2000 FSF E181 Model 2000 FSC Model 2000 FSF E255 E256 E257 E266 E277 E166 E167 E168 E333 E292 E293 E555 No Weld Chain Assembly E305 E306 E307 E144 Entire FSC System E301 E242 E194 E132 E13...

Page 24: ...0 No Weld Chain Assembly E305 E306 E307 E185 Fail Secure System Model 1000 FSF Entire Kit E301 E255 E256 E257 E266 Model 1000 FSF E281 Model 1000 FSC E278 E169 E145 E241 E132 E198 E133 E444 E293 E292...

Page 25: ...E031 Motor Harness E032 Receiver Harness E525 Plastic Eagle Logo E300 No Weld Chain Assembly Complete E305 Chain Bracket E306 Chain Bolt w Nuts E307 U Bolts E444 Operator Cover E293 Plastic Control B...