21
4. AUTOMATIC CLOSING&TIME SETTING
NOTE: We recommend that Safety Photo Beams be
used in any installation where the Auto Close function
is enabled.
a. Press and hold the
SET
Button until“1”appears on the
display, next press the
UP
button until “4” appears on
the display to enter this function setting then release
the button.
b. Press the
SET
button again, the unit is now in automatic
close adjustment mode. And then you will see a figure
“0” with flash dot appears on the display.
c. Press
UP / Down
button once to set the auto close
time (0~9).
d. Press the
UP
button to increase the time, or the
DOWN
button to decrease the time.
The close time is 15second*N, N=0~9. The maximum
time is 135s. To disable Auto Close Function, set time to
zero (0).
e. Press the
SET
button to confirm the set and it will back
to standby status automatically and display “ll”.
NOTE
:
• The closing time is set on “0” as standard in factory.
• If the Photo Cell Function is on, and it’s broke by the
obstruction, the auto close time will stop for a while,
and then continue the automatic close time again.
PROGRAMMING INSTRUCTIONS
INCREASE TIME
DECREASE TIME