23
6. LED OFF DELAY TIME SETTING
a. Press and hold the
SET
Button until “1” appears on the
display, next press the
UP
button until “6” appears on
the display to enter this function setting then release
the button.
b. Press the
SET
button again. The unit is now in LED off
delay time adjustment mode. And then you will see a
figure“3”with flash dot appears on the display.
c. Press
UP / Down
button once to set the LED off delay
time (1~9).
d. Press
UP
button to increase the time, or
DOWN
button
to decrease the time.
The delay time is 1 minute*N, N=1~9. The maximum delay
time is 9 minutes.
e. Press the
SET
button to confirm the set and it will back
to standby status automatically and display “ll”.
NOTE
: The LED off delay time is set on “3” as standard in
factory.