North American - ENG
Date Released:
05-22-18
TAM Application Monitor - Yype 21800
Page 36
44-0009-2048-6 / ECO# 0078483
Input Output Registers
Timers Description
000
Current
Sensor
001
UPPER – Low Tape Proximity Sensor
002
Photo Eye - Box Present Sensor
003
LOWER – Low Tape Proximity Sensor
004
LOWER – Tape Dispense Proximity Sensor
005
SPARE - Not in Use
006
UPPER – Tape Dispense Proximity Sensor
007
SPARE - Not in Use
500
SPARE - Not in Use (AC Voltage Common)
501
“Optional” Remote AC (120/240) Beacon Light
502
Case Sealer - Solid State Relay
503
“Optional” Dry Contact Relay. This output is used to stop an 800rks or 800rf
in the event of a fault condition. This output could also be used to halt an
external conveyor or signal a host controller. Output is normally ON and is
OFF under a fault condition.
504
SPARE - Not in Use (DC Voltage Common)
505
Panel Indicator Light 24V DC
DM0075
System
Con
fi
guration Register (31=Lower Only, 32=Upper Only,
3=Both Taping Heads). Factory setting DM0075 = 33.
DM0080
By-Pass Register (1=By-Pass Enable, <>1 = Normal TAM Operation.
Factory setting DM0080 = 0.
DM0100
Taping Head o
ff
set distance (0 = Standard 1 = O
ff
set).
DM0105
Case Sealer Belt Speed (0=15 ips 1=20 ips 2=30 ips).
TH051
Represents the distance in “time” from the box present sensor to within ½”
from the end of the lower taping head cut-o
ff
bracket (i.e. just before the
tape would cut). When possible the box present sensor should be positioned
very near the lower taping head cut-o
ff
bracket so the value of TH051 is small.
In cases where this is not possible position the sensor just in front of the
lower taping head apply roller. However, if there is no lower taping head
used then position the box present sensor as close to the upper cut-o
ff
bracket.
Note:
In all cases position the sensor to trigger before the tape would cut.
As an example for a 15 ips case sealer belt speed and a box present
sensor positioned to trigger ½” before the tape would cut TH051,
would be set to 3 hundreds of a second [TH051 = distance/velocity =
(1/2/15)*100]. In applications where only an upper taping head is
used (i.e. DM0075 = 32) TH051 represents the time in hundreds of
a second from the box present sensor to just before the upper taping
head cuts. Factory Setting TH051 = 2.
Please refer to table II below for PLC inputs, outputs, special “settable” internal control registers and settable
internal timers with accompany description.
PLC Memory Map
Summary of Contents for Tape Application Monitor
Page 6: ...5...