North American - ENG
Date Released:
05-22-18
TAM Application Monitor - Yype 21800
Page 8
44-0009-2048-6 / ECO# 0078483
Machine Set-Up
Receiving And Handling
After the machine has been unpacked, examine the
components thoroughly for damage that might have
occurred during transit.
If damage is evident,
fi
le a
damage claim immediately
with the transportation
company and also notify your 3M Representative.
T
he following instructions are presented in the order
recommended for installing the Tape Application Moni-
toring Kit on your 3M-Matic
™
case sealer.
The control box is mounted directly to the case sealer
using the control box mounting bracket.
For models: 200a, 800ab, 800asb, 800r, 800rks,
800rf, 7000a, 7000r, 8000a, and 8000af the
recommended mounting position is on the on/o
ff
push-button side of the case sealer.
Refer to
Figures 2-1 through 2-5.
For models: 800rks and 800rf the recommended
mounting position is on the underside of the machine’s
electrical control box.
Control Box Assembly
Note:
Because holes do not already exist in the
electrical box of the 800rks and 800rf you
must
fi
rst position the control box mounting
bracket then carefully mark and drill clearance
holes (.343” dia.) for the (2) M8 mounting
fasteners. Refer to
Figures.
Installation – General
Read the installation instructions completely before
beginning installation. For future reference, record
the Tape Application Monitoring Kit serial number on
the front cover of this instruction manual in the space
provided for future reference.
•
To reduce the risk associated with
mechanical and electrical hazards:
−
Read, understand, and follow all safety
and operating instructions before
operating or servicing the case sealer.
−
Allow only properly trained and quali
fi
ed
personnel to operate and service this
equipment.
Warning
Warning
•
To reduce the risk associated with
hazardous voltage:
−
Position electrical cord away from foot and
vehicle tra
ffi
c.
Installation and Set-Up
Summary of Contents for Tape Application Monitor