background image

North American - ENG

Date Released:

05-22-18

TAM Application Monitor - Yype 21800                                     
Page 10
44-0009-2048-6 / ECO# 0078483

The  taping head tape drum bracket angle must be 

determined to properly position the Lower Dancer Arm 

assembly.  Refer to 

Figures 2-6 and 2-7

 to determine 

which example represents the current machine 

con

fi

 guration.

1)  Remove the lower taping head supply roll 
2)   Properly position the taping head inside the case  

 sealer 

cavity. 

 

3)   Position the Lower Dancer Arm spring post in 

 

the appropriate location.  The factory spring 

 post 

setting 

(Figure 2-8)

 corresponds to the    

 

bracket angle shown in 

Figure 2-6.

  The spring  

 

post must be moved 

(Figure 2-8)

 as the bracket  

 

angle changes to keep the dancer arm roller in 

 

contact with the tape drum 

(Figure 2-7).

Important:

   The spring post must be in the 

 

 

appropriate location to determine the  

 

 

correct mounting location.

 

4)  Place and hold the lower dancer arm assembly 

 

on the bottom of the right hand drive frame so 

 

the dancer arm roller is in contact with the tape 

 drum 

(Figures 2-6 and 2-7).

Note:

   Right hand is de

fi

 ned by viewing the machine  

 

from the entrance end.

5)   Place a mark on the case sealer frame at

 

the back of the dancer arm bracket 

 

(Figure 2-6 and 2-7).

The lower dancer arm assembly is mounted directly 

to the case sealer’s right hand lower drive frame using 

the nut plate, M6 screws (2) and washers (2) supplied 

in this kit.   Mounting holes must be drilled in the lower 

drive frame on all case sealer models.

Lower Dancer Arm

Note: 

  This kit contains components to monitor both  

 

an upper and lower taping head on a single 

 

case sealer.  Outboard tape supply roll 

 

mounting is possible with an optional 

 

lower to outboard conversion kit 

 (See 

"Options/Accessories").

Lower Dancer Arm Mounting 

Figure 2-6

Figure 2-7

 Place Mark Here

 Spring

 Post

 Place Mark Here

Figure 2-8

Figure 2-9

Installation and Set-Up 

 

(continued)

Summary of Contents for Tape Application Monitor

Page 1: ...S EQUIPMENT Read understand and follow all safety and operating instructions Spare Parts It is recommended you immediately order the spare parts listed in the Spare Parts Service Information section T...

Page 2: ...ance troubleshooting repair work and servicing plus parts list of the 3M Matic TM Tape Application Monitor TAM 3M Industrial Adhesives and Tapes 3M Center Building 220 5E 06 St Paul MN 55144 1000 Edit...

Page 3: ...dhesives and Tapes 3M Center Building 220 5E 06 St Paul MN 55144 1000 Technical Assistance Replacement Parts and Additional Manuals Fortechnical assistance contact our help line at 1 800 328 1390 Prov...

Page 4: ...ed with each machine is an Instructions and Parts List manual SERVICE REPLACEMENT PARTS AND ADDITIONAL MANUALS AVAILABLE DIRECT FROM Order parts by part number part description and quantity required A...

Page 5: ...Lower Outboard Dancer Arm Assembly Upper Arm Assembly Box Present Sensing Assembly Mounting Procedure Attaching the Brackets Adjusting the Low Tape Sensor Setting the PLC Application Parameters Theor...

Page 6: ...5...

Page 7: ...se sealer when a tape related malfunction occurs In addition the control system will turn on an indicator light that is located on the control panel Equipped with the ability to control up to two Accu...

Page 8: ...amage aris ing from this 3M equipment whether direct indirect special incidental or consequential regardless of the legal theory asserted including breach ofwarranty breach of contract negligence or s...

Page 9: ...ymbol identifies important messages in this manual READ AND UNDERSTAND THEM BEFORE INSTALLING OR OPERATING THIS EQUIPMENT To reduce the risk associated with mechanical and electrical hazards Read unde...

Page 10: ...In the event the following safety labels are damaged or destroyed they must be replaced to ensure operator safety Replacement part numbers for individual labels are shown in the following figure and a...

Page 11: ...Skill 2a Electrical Maintenance Technician This operator is trained to use the machine as the MA CHINE OPERATOR and in addition is able to work with thesafetyprotectiondisconnected tomakeadjustments...

Page 12: ...been designed and tested to work with the following 3M Matic case sealers 200a 800ab 800asb 800r 800rks 800rf 7000a 7000r 8000a and 8000af Additional information is required for 800rks and 800rf appl...

Page 13: ...l box One spare strain relief cord grip PG 7 is available for ad ditional input and or output control signals Examples of control signals include disabling a remote conveyor interfaceto a host control...

Page 14: ...rf the recommended mounting position is on the underside of the machine s electrical control box Control Box Assembly Note Because holes do not already exist in the electrical box of the 800rks and 80...

Page 15: ...5 22 18 TAM Application Monitor Yype 21800 Page 9 44 0009 2048 6 ECO 0078483 Figure 2 1 200a 7000a Pro 7000r Pro Figure 2 2 800ab 800asb 8000a Figure 2 3 800r Figure 2 4 8000af Figure 2 5 800rf 800rks...

Page 16: ...ine the correct mounting location 4 Place and hold the lower dancer arm assembly on the bottom of the right hand drive frame so the dancer arm roller is in contact with the tape drum Figures 2 6 and 2...

Page 17: ...a 0 25 inch 6 5mm hole at the marks made in step 7 Note Carefully remove any burrs on the case sealer frame before fastening the dancer arm assembly 9 Fasten the dancer arm assembly to the case seale...

Page 18: ...he appropriate bracket See Figures 2 12 using the M6 screws and washers 2 Remove the tape supply roll from the upper tape drum 3 Remove the fasteners used to secure the tape drum bracket to the inner...

Page 19: ...lications with top taping only the position should be chosen using the upper taping head cutoff bracket The sensor must also be positioned to detect the lowest height box withoutbeingblockedbytapinghe...

Page 20: ...as it passes through the machine 9 Mark the final position 7 Slide the sensor and reflector brackets as required until the light LED on the sensor turns On Note The sensor LED is On whenever the senso...

Page 21: ...re marked to indicate the appropriate sensor connection i e UD Upper Dispensing sensor US Upper low tape Supply sensor LD Lower Dispensing sensor LS Lower low tape Supply sensor Important Cables must...

Page 22: ...f this manual for further information on this feature The sensor should be positioned to allow the opera tor ample time to replace the tape roll before ad versely affecting your production process whe...

Page 23: ...erify the screen shown is displayed on the HMI unit Figure 2 18 Press the SYS CONFIG Page to displaythe HMI display shown in Figure 2 19 Starting with the taping heads to monitor press the lower left...

Page 24: ...esents the maximum time to process a box before enabling a fault condition Typically if this time is exceeded a box jam has occurred and the case sealer is shut down to prevent premature belt wear Fig...

Page 25: ...velocities to ensure that both the tape apply and cut velocities are in acceptable ranges after setup When completed press the PAGE EXIT to return to the main menu To reduce the risk associated with...

Page 26: ...configura tion and operating parameters for the application Operational Explanation The box present sensor assembly consists of a reflec tor and a sensor mounted on opposite sides of the case sealer...

Page 27: ...ape applied successfully between positions illustrated in Figures 3 2 to 3 3 A fault will be generated if either condition is satisfied The first filter is a general calculation that compares the calc...

Page 28: ...and stop after the tape is cut and ve locity V2 will be significantly less than V1 The sys tem compares V2 to V1 and if that value is greater than 60 of V1 a TAPE DID NOT CUT fault will be generated a...

Page 29: ...d Simply lift from the case sealer to replace the supply roll Place the taping head back into the machine with the new tape roll Figure 4 2 4 Verifythatthesupplyrolliscontactthedancerarm roller for pr...

Page 30: ...display and note the values that appear on the screen after box goes through machine Verify both the apply and cut values i e velocities inches sec for each taping head being used In general the expe...

Page 31: ...not apply to box Check tape supply roll Tape is broken not on taping head apply roller or supply roll is empty Correct then RESET by pressing the Start PB on case sealer LOWER Taping Head Tape did not...

Page 32: ...or TAM to monitor properly Insure to allow a minimum gap of 18 inches between boxes RESET by pressing the Start PB on the case sealer LOWER Taping Head Internal overflow error PLC error or LOWER TAPE...

Page 33: ...ER Taping Head Internal overflow error Refer to the trouble shooting section 25 Box Jam Case Sealer Disabled 66 BOX INTERVAL ERROR Boxes too close together Refer to the trouble shooting section Operat...

Page 34: ...the application as follows Reference Settable Timers section in this manual TH051 2 FACTORY SETTING Represents the time for the leading edge of the box to travel from box present sensor to the tape h...

Page 35: ...ed press the PAGE EXIT to return to the main menu Example Timer TH051 Calculation 1 Example Timer TH051 Calculation 2 Belt Speed Distance from box presence sensor to lower cut off bracket of taping he...

Page 36: ...outer knurled surface of the roller is clean and not greatlyworn If any ofthe above conditions occur this could cause the roller to slip and not properly turn in response to a turning tape supply rol...

Page 37: ...edge of the box to travel from the box present sensor to within of the end of the cutoff bracket for lower taping head If only the up per taping head is monitored adjust to within of the upper head s...

Page 38: ...North American ENG Date Released 05 22 18 TAM Application Monitor Yype 21800 Page 32 44 0009 2048 6 ECO 0078483...

Page 39: ...or when the operator presses the ON push button of the case sealer after an error has occurred When PLC input 000 is off all inputs are ignored and tape monitoring will not take place until the case s...

Page 40: ...ECO 0078483 Electrical Diagram To reduce the risk associated with pinches entanglement and hazardous voltage Turn electrical supply off and disconnect before performing any adjustments maintenance or...

Page 41: ...2048 6 ECO 0078483 Electrical Diagram To reduce the risk associated with pinches entanglement and hazardous voltage Turn electrical supply off and disconnect before performing any adjustments maintena...

Page 42: ...stance 0 Standard 1 Offset DM0105 Case Sealer Belt Speed 0 15 ips 1 20 ips 2 30 ips TH051 Represents the distance in time from the box present sensor to within from the end of the lower taping head cu...

Page 43: ...ter indicator of post cut conditions but allows the box to travel further i e escape the case sealer before turning off the case sealer in the advent of a fault This value is typically set at 80 100 h...

Page 44: ...following spare parts be ordered and kept on hand Qty Part Number Description 2 26 1006 1320 2 Fuse Slo Blow 5X20mm 1 25A Littelfuse 2181 25 Part Number Option Accessory For additional information on...

Page 45: ...ber Part Number and Part Description for the parts on that illustration Note The complete description has been included for standard fasteners and some commercially available components This has been...

Page 46: ...North American ENG Date Released 05 22 18 TAM Application Monitor Yype 21800 Page 40 44 0009 2048 6 ECO 0078483...

Page 47: ...an ENG Date Released 05 22 18 TAM Application Monitor Yype 21800 Page 41 44 0009 2048 6 ECO 0078483 Tape Application Monitor TAM Figure 6 1 Figure 6 3 Figure 6 6 Figure 6 4 Figure 6 5 Frame Assemblies...

Page 48: ...Date Released 05 22 18 TAM Application Monitor Yype 21800 Page 42 44 0009 2048 6 ECO 0078483 Figure 6 1 Tape Application Monitor TAM 12 4 18 18 17 1 16 17 20 21 11 15 10 16 7 8 2 6 9 9 13 11 17 17 22...

Page 49: ...26 1014 8755 6 Capscrew Soc Hd Dr M6 X 1 0 X 16mm Lg Stl Zn Plt 12 12 7990 7756 0 Screw Shoulder Hex Soc Dr 5 16 Dia X 62 Lg A Stl 13 26 1016 2494 3 Nut Loc Hex Nylon Insert Steel 1 4 20 A Stl Zn Plt...

Page 50: ...North American ENG Date Released 05 22 18 TAM Application Monitor Yype 21800 Page 44 44 0009 2048 6 ECO 0078483 Figure 6 2 Tape Application Monitor TAM 11 9 2 8 1 5 3 8 11 7 9 13 14 12 15 9 4 6 10...

Page 51: ...n Plt 7 26 1016 2494 3 Nut Loc Hex Nylon Insert Steel 1 4 20 A Stl Zn Plt 8 26 1016 2466 1 Sensor Prox NPN 2mm M8 Omron E2A S08KS02 M5 C1 9 26 1000 0010 3 Washer Plain A Stl Narrow M6 10 26 1016 2496...

Page 52: ...North American ENG Date Released 05 22 18 TAM Application Monitor Yype 21800 Page 46 44 0009 2048 6 ECO 0078483 Figure 6 3 Tape Application Monitor TAM 8 6 1 2 3 9 4 5 7 8...

Page 53: ...ft Roller 4 78 8137 0006 5 Roller Assembly 5 78 8656 4012 8 Ring Retaining E Ring Waldes 5133 50 1 2 Shaft 6 26 1014 8756 4 Capscrew Hex Soc Dr M6 X 1 0 X 20mm Lg Zn Plt 7 26 1014 8755 6 Capscrew Hex...

Page 54: ...North American ENG Date Released 05 22 18 TAM Application Monitor Yype 21800 Page 48 44 0009 2048 6 ECO 0078483 Figure 6 4 Tape Application Monitor TAM 5 4 1 2 3 6...

Page 55: ...r 2 78 8017 9318 9 Washer Plain M8 Narrow A Stl Zn Plt 3 26 1016 2500 7 Capscrew Hex Hd M8 X 1 0 X 16mm Lg A Stl Zn Plt 4 26 1014 8756 4 Capscrew Hex Soc Dr M6 X 1 0 X 20mm Lg Zn Plt 5 26 1000 0010 3...

Page 56: ...tion Monitor Yype 21800 Page 50 44 0009 2048 6 ECO 0078483 Tape Application Monitor TAM Figure 6 5 45 44 46 25 59 30 5 1 20 4 52 42 32 41 6 7 29 31 12 11 9 10 8 39 27 28 54 53 36 37 65 62 61 26 35 19...

Page 57: ...88 3 Strain Relief Straight LiquidTight Thru 114 250 Dia PG 7 Hub Heyco 3208 32 26 1011 5441 2 Strain Relief Straight LiquidTight Thru 230 395 Dia PG11 Hub Heyco 3214 35 26 1016 2483 6 Relay Solid Sta...

Page 58: ...North American ENG Date Released 05 22 18 TAM Application Monitor Yype 21800 Page 52 44 0009 2048 6 ECO 0078483 Figure 6 6 Tape Application Monitor TAM 1 1 3 5 3 4 2 6...

Page 59: ...t Bed Sensor 2 26 1016 2470 3 Switch PhotoElectric W Reflector Omron E3F2 R2C4 P1 3 26 1014 5501 8 Washer Plain M3 Narrow A Stl Zn Plt 4 DY 1102 0041 6 Capscrew Button Hd Soc Dr M3 X 12mm Lg A Stl Zn...

Page 60: ...North American ENG Date Released 05 22 18 TAM Application Monitor Yype 21800 Page 54 44 0009 2048 6 ECO 0078483...

Page 61: ...North American ENG Date Released 05 22 18 TAM Application Monitor Yype 21800 Page 55 44 0009 2048 6 ECO 0078483...

Page 62: ...North American ENG Date Released 05 22 18 TAM Application Monitor Yype 21800 Page 56 44 0009 2048 6 ECO 0078483...

Reviews: