North American - ENG
Date Released:
05-22-18
TAM Application Monitor - Yype 21800
Page 7
44-0009-2048-6 / ECO# 0078483
Speci
fi
cations
(continued)
Warning Panel LED Indicator:
O
ff
: Normal operation
On: (1) Power up light test - Momentary
(2) Tape application fault - Flashing
(3) Low tape - Continuous
Remote Warning Beacon Light
(Optional)
:
A din rail is used in the electrical control box to mount
the primary components. Space is available on the din
rail to mount one additional terminal block or an optional
dry contact relay (See "Options/Accessories").
Strain relief cord grips are used to pass both control and
power into and out of the electrical control box. One
spare strain relief cord grip (PG 7) is available for ad-
ditional input and/or output control signals. Examples
of control signals include disabling a remote conveyor,
interface to a host control or interface to an 800rks and
800rf case sealer PLC)
Electrical Control Box
The remote warning beacon light performance is identi-
cal to the panel mounted LED. The beacon light allows
operators and maintenance personnel to observe fault
conditions from a distance away from the case sealer.
Control Box Dimensions:
W
L
H
mm 267
229
114
[Inches]
[10.5]
[9]
4.5]
Weight:
14.5 kg [32 lbs.] Packaged
Indicator Lamp
Remote Warning
Beacon Light
Strain Relief
Cord Grips
Note:
The Electrical Control box is equipped with
the connection for the Remote Warning
Beacon Light, no additional wiring is required.
Figure 1-1
Figure 1-2
Figure 1-3
Summary of Contents for Tape Application Monitor
Page 6: ...5...