Operation
(continued)
FAULT CODE "66"
FAULT CODE "121"
FAULT CODE "221"
FAULT CODE "25"
BOX INTERVAL ERROR: Boxes too close
together for TAM to monitor properly. Insure
to allow a minimum gap of 18 inches between
boxes. RESET by pressing the Start PB on the
case sealer
LOWER Taping Head: Internal over
fl
ow
error. PLC error or LOWER TAPE DISPENSE
proximity sensor issue. RESET. Press the
Start PB on the case sealer
UPPER Taping Head: Internal over
fl
ow
error. PLC error or LOWER TAPE DISPENSE
proximity sensor issue. RESET. Press the
Start PB on the case sealer
BOX JAM: Case Sealer Disabled
RESET: Press Start PB on case sealer