34
3M™MicroTouch™ System DST2270DX Integration Guide
3M Touch Systems, Inc. Proprietary Information – TSD-25739
CHAPTER 4
Installing the Controller
This chapter describes how to install the controller for use with 3M™ MicroTouch™
DST sensor. For complete information, refer to the DX123 Controller Reference Guide
(P/N TSD-33532).
Note:
The DST sensor works exclusively with a mated DX123 controller for optimal
performance. Be sure to match the serial number on the sensor with the serial number on
the controller throughout the integration process.
This chapter assumes you have already disassembled the display and mounted the sensor
to the front of the LCD. For information on completing these procedures, refer to
Chapters 2 & 3.
After you integrate the sensor, return to this chapter for the following information:
•
Mounting the controller
•
Supplying power to the controller
•
Connecting the controller to the computer
Disassembling the Chassis
Note:
When handling the 3M™ MicroTouch™ DST2270DX sensor and associated
electronics, make sure you wear an ESD strap to prevent electrostatic discharge to
electrical components on the sensor.
1.
Remove the screws securing the display’s control panel cover to the chassis. Be sure
to save and label these screws for reassembly.
2.
Take a moment to inspect the display’s internal hardware before you disconnect any
wires.
a.
Note where each wire is attached and how each wire is routed.
b.
Label each wire. Labeling the wires makes reassembling easier.