2.2 Laser Safety
The SLA 750 uses a UV (ultraviolet) solid-state frequency tripled Nd:YVO4 laser which utilizes a 355 nm wavelength laser with a
maximum power output of 3 watts at the vat (EN/IEC 60825-1:2014). The laser is located in the Printhead area of the SLA 750.
The SLA 750 is a Class I (1) laser product. Class 1 products are not considered harmful and require no special safety precautions
under normal operating conditions. The laser beam is completely confined. The viewing windows in the Print Chamber block
the UV laser radiation from exposure outside of the print area.
Laser Radiation: Operating the equipment or performing procedures other than those specified within this
guide may result in exposure to hazardous, invisible laser radiation.
Laser Radiation: Never stare directly into a laser beam, nor into any beam reflection, whether diffused or
from a mirror-like surface.
Laser Radiation: During normal operation, and with all panels installed, the SLA 750 is classified as a Class I (1)
laser device . If any of the interlocks are defeated, the SLA 750 becomes a Class IV (4) device . Eye damage can
occur by looking directly into the beam or by viewing any type of beam reflection
Laser Radiation: Interlocks are to be defeated only by trained personnel when needed during service
procedures.
Embedded Laser Specifications
• Max output of laser radiation: 3W max average power
• Pulse duration: 10 ns, 80 kHz
• Emitted wavelength(s): 355 nm
• Name and publication date of the standard: EN/IEC 60825-1:2014
Control Switches
The locations of control switches are illustrated in the section Printer - Outside View. Master and Emergency power shut-off
switches are described in the following paragraphs.
Master Power Shut-off
The SLA 750 has a master circuit breaker switch located on the electrical cabinet module on the right side of the machine.
Emergency Stop
All SLA 750 printers have (3) Emergency Stop (E-Stop) buttons on the left-side of the UI panel, inside the print chamber and laser
assembly. They are bright red with a yellow background. Pressing one cuts power to all moving axes, closes the laser shutter,
and puts the laser in safe mode. To release the E-Stop, pull it out and turn it clockwise. The system cannot run while an E-Stop is
depressed. The SLA 750 Dual will have an additional E-Stop on its B-side Laser Assembly in the identical location seen below.
3D Systems, Inc.
3
p/n 40-D150, Rev. C
Summary of Contents for SLA 750 Series
Page 1: ...User Guide Release Date 6 6 2023 Original Instructions ...
Page 13: ...Front of SLA Vat Inside of printer 3D Systems Inc 9 p n 40 D150 Rev C ...
Page 34: ...3D Systems Inc 30 p n 40 D150 Rev C ...
Page 40: ...3D Systems Inc 36 p n 40 D150 Rev C ...
Page 51: ...3D Systems Inc 47 p n 40 D150 Rev C ...
Page 63: ...1 Select Smart Support icon 9 2 Select Create 10 3D Systems Inc 59 p n 40 D150 Rev C ...
Page 75: ...5 Slowly back the build platform out of the printer 3D Systems Inc 71 p n 40 D150 Rev C ...
Page 94: ... On Position Off Position 3D Systems Inc 90 p n 40 D150 Rev C ...