![3D Platform 3DP1000 User Manual Download Page 9](http://html1.mh-extra.com/html/3d-platform/3dp1000/3dp1000_user-manual_441968009.webp)
www.3DPlatform.com |
7
Original Instructions 2015
BEFORE USING THE PRINTER
Safety First!
This printer is intended for professional use by an operator with at least basic knowledge of electronics,
mechanics, and computers in general. Use by unqualified persons may be dangerous to the user and/or damaging to the
printer. Printer damage due to mis-use is not covered by the warranty. Follow all safety guidelines within this manual.
INITIAL ACTUATOR ALIGNMENT
Prior to powering up the machine, move the X axis to the
end of the build area, as shown. Gently push both sides
simultaneously
so the actuators move smoothly until
they reach the end. This will eliminate any racking
1
or
misalignment that occurred during shipping.
POWERING UP
Plug in the power cord for the printer and bed heater.
Once the unit is plugged in, turn it on using the button
located on the control panel and the front of the
machine. Note: Machines sold prior to 12/4/15 have
two power cords and do not have power buttons on the
front of the machine.
The control panel is located inside of the enclosure
toward the front of the printer.
In case of emergency, press one of the Emergency Stop
buttons (located on the front and rear of the machine).
For machines sold prior to 12/4/15, press the Power Off
button located on the front of the electrical panel.
1
Note: Racking of linear motion actuators can cause serious damage
or breakage to mechanical hardware and/or bracketry on the
3DP1000
printer. Follow the
Initial Actuator Alignment
process
to reduce the risk of racking.
Initial alignment of the actuators must
be completed prior to powering up!
Example of Racking – To Be Avoided
Standard Machine
Machines sold prior to 12-4-15
Power Located Inside Cart
Initial Setup
Link to electrical wiring diagram