334
C
HAPTER
12: F
ILE
S
YSTEM
M
ANAGEMENT
Table 396
Enable/Disable Info-Center
Info-center is enabled by default. After info-center is enabled, system
performances are affected when the system processes much information because
of information classification and outputting.
2
Configuring to output information to Telnet terminal or dumb terminal
Perform the following operation in System View.
Table 397
Configuring to Output Information to Telnet Terminal or Dumb Termina
l
3
Configuring information source on the Switch
With this configuration, you can define the information that is sent to the Telnet
terminal or dumb terminal that is generated by which modules, information type,
information level, and so on.
Perform the following operation in System View:
Table 398
Defining Information Source
modu-name
specifies the module name;
default
represents all the modules;
level
refers to the severity levels;
severity
specifies the severity level of information.
The information with the level below it will not be output.
channel-number
specifies the channel number and
channel-name
specifies the channel name.
When defining the information sent to Telnet terminal or dumb terminal,
channel-number
or
channel-name
must be set to the channel that corresponds to
the Console direction.
Every channel has been set with a default record, whose module name is
default
and the module number is 0xffff0000. However, for different channels, the default
record may have different default settings of log, trap and debugging. When there
is no specific configuration record for a module in the channel, use the default
one.
When there are more than one Telnet users or monitor users at the same time,
some configuration parameters should be shared among the users, such as
module-based filtering settings and severity threshold. When a user modifies these
settings, it will be reflected on other clients.
Operation
Command
Enable info-center
info-center enable
Disable info-center
undo info-center enable
Operation
Command
Output information to Telnet terminal or dumb
terminal
info-center monitor channel {
channel-number
|
channel-name
}
Cancel the configuration of outputting
information to Telnet terminal or dumb terminal
undo info-center monitor
channel
Operation
Command
Define information source
info-center source {
modu-name
| default }
channel {
channel-number
|
channel-name
} [ { log
| trap | debug }* { level
severity
| state
state
}* ]
Cancel the configuration
of information source
undo info-center source {
modu-name
| default }
channel {
channel-number
|
channel-name
}
Summary of Contents for SuperStack 4
Page 6: ...18 ABOUT THIS GUIDE ...
Page 34: ...46 CHAPTER 1 GETTING STARTED ...
Page 62: ...74 CHAPTER 3 VLAN OPERATION ...
Page 69: ...PoE Configuration 81 ...
Page 70: ...82 CHAPTER 4 POWER OVER ETHERNET POE CONFIGURATION ...
Page 98: ...110 CHAPTER 5 NETWORK PROTOCOL OPERATION ...
Page 220: ...232 CHAPTER 8 ACL CONFIGURATION ...
Page 408: ...420 CHAPTER B RADIUS SERVER AND RADIUS CLIENT SETUP ...
Page 432: ...444 APPENDIX D 3COM XRN ...