5-8
C
HAPTER
5: T
ROUBLESHOOTING
■
Remove all other NICs from the computer and run the
tests again. If the tests pass, the other NICs may be
causing contention.
■
Check the configuration settings and change them if
they conflict with another device. See Chapter 6.
Make sure you are running the latest BIOS for your PC.
Changing the Test Setup
To change the test setup, follow these steps:
1 Select Test Setup from the Test menu in the main
window of the Configuration and Diagnostic
Program, or select the Test Setup button in the
Run Tests dialog box.
2 Press [Tab] to select any Test Setup dialog box field.
3 To change a setting in a field, follow these steps:
a
In the Group Select box, use the arrow keys to select a
test group.
b
In the Group X
Tests box, use the arrow keys to select
a test. Press the [Space Bar] to enable or disable an
individual test.
c
In the Repetitions box, specify the number of times
you want to run the tests, or use the arrow keys to
select the
Continuous
option.
d
In the Errors box, press the [Space Bar] to select or
deselect the
Halt on Error
parameter.
4 Select OK, and then press [Enter].
5 Select Run Tests from the Test menu.
6 Select Start to run the tests.