Running the Diagnostic Tests
5-5
Select
Echo Server
under the
Test
menu, and click the
Start
button to make the computer an echo server.
If you are setting up an echo server on a computer with a
10 Mbps 3Com NIC
other than
a 3C515-TX NIC, follow
these steps:
1 Select a computer to use as an echo server.
2 Insert the appropriate EtherDisk diskette into the
echo server computer’s drive A.
If the computer has a Fast EtherLink XL NIC (3C900-TX,
3C905-TPO, or 3C905-COMBO) installed, use the 3C90X
EtherDisk
diskette.
Otherwise, use the
EtherDisk
diskette that came with
the NIC.
3 On the echo server computer, change to drive A at
the DOS prompt. Type the following to start the
Configuration and Diagnostic Program:
3cxxx [Enter]
where the XXX is the program name for a 10 Mbps NIC
indicated in Table 5-2, which corresponds to the type of
10 Mbps NIC in the echo server.
4 From the main menu, select Echo Server Setup.
The program notifies you that your computer is now
set up as an echo server. To run the test, follow the
instructions in “Starting the Group 3 Test.”
Table 5-2
NIC and Diagnostic Program Names
Diagnostic Program Name
Echo Server NIC
3C503
EtherLink II
or II TP
EtherLink II/16 or II/16 TP
3C505
EtherLink Plus
3C507
EtherLink 16 or EtherLink 16 TP
3C5X9CFG
EtherLink III family
3C59XCFG
Fast EtherLink
3C90XCFG
Fast EtherLink XL