5 -6
Chapter 5: P e rfo rm in g T ro u b le s h o o tin g a n d D ia g n o stic Tests
3 Start the diagnostic program on the echo server.
The diagnostic program that you use depends on the adapter that
is installed in the echo server. After the system prompt p f the drive
containing the Configuration and Diagnostic Program, enter the
name of the appropriate program (for example, 3C523) from
Table 5-1.
Table 5-1
Diagnostic Programs
Diagnostic
Program Name
Adapter in the Echo Server
3C503
EtherLink II® or II TP, EtherLink 11/16 or 11/16 TP
3C505
EtherLink Plus®
3C507
EtherLink 16 or EtherLink 16 TP
3C5X9CFG
EtherLink III family
3C523
EtherLink/MC
3C523TP
EtherLink/MC TP
3C527
EtherLink/MC 32
4 In the Diagnostic and Configuration Program main window,
select Echo Server from the Test menu on the menu bar.
The program notifies you that your computer is now set up as an
echo server.
Starting the G roup 3 Test
To run the Group 3 test on an EtherLink III adapter, follow these steps:
1 Start the Configuration and Diagnostic Program.
This program must be on the computer containing the adapter
you want to test.
2 Select Test Setup from the Test menu.
3 Enable the Group 3 test. Highlight <OK> and press [Enter].
4 Go to the Run Tests dialog box to start the tests.