2N TELEKOMUNIKACE a.s., www.2n.cz
70/104
SendWiegandCode
The
block defines the action for sending of an entered code to
SendWiegandCode
another device via the Wiegand interface.
Parameters
– define the event to launch the action.
Event
– define the condition to be met to execute the action. This parameter
Condition
is optional.
– define the code to be sent via the Wiegand interface. If the entered code
Code
exceeds the capacity of the message transferred via the Wiegand interface, the
high-order bits are cut.
Valid values:
decimal number
– facility code. The setting applies only to "wiegand26".
Facility code
Valid values:
decimal number in a range of
0 –255
The parameter is optional; if not set, then unused.
– define the format of the message sent via Wiegand.
Format
Valid values:
– 26 bits
wiegand26
– 32 bits
wiegand32
– 37 bits
wiegand37
The parameter is optional; the default value is
.
wiegand26
– define the module via which the code is to be sent.
Module
Valid values:
module name configured in the Module name parameter in the
Hardware / Extenders / Modules / Wiegand module menu.
The parameter is mandatory for Verso but not applied for other models.
Summary of Contents for IP series
Page 1: ...www 2n cz Automation manual for 2N IP intercoms Configuration Manual Version 2 22 ...
Page 18: ...2N TELEKOMUNIKACE a s www 2n cz 18 104 Example Event generated upon detection of DTMF code ...
Page 28: ...2N TELEKOMUNIKACE a s www 2n cz 28 104 ...
Page 30: ...2N TELEKOMUNIKACE a s www 2n cz 30 104 ...
Page 33: ...2N TELEKOMUNIKACE a s www 2n cz 33 104 ...
Page 43: ...2N TELEKOMUNIKACE a s www 2n cz 43 104 ...
Page 51: ...2N TELEKOMUNIKACE a s www 2n cz 51 104 ...
Page 54: ...2N TELEKOMUNIKACE a s www 2n cz 54 104 ...
Page 57: ...2N TELEKOMUNIKACE a s www 2n cz 57 104 ...
Page 60: ...2N TELEKOMUNIKACE a s www 2n cz 60 104 ...
Page 94: ...2N TELEKOMUNIKACE a s www 2n cz 94 104 tamper switch if installed tamper ...