![2N IP series Automation Manual Download Page 42](http://html.mh-extra.com/html/2n/ip-series/ip-series_automation-manual_439915042.webp)
2N TELEKOMUNIKACE a.s., www.2n.cz
42/104
RegistrationStateChanged
The
block defines the event generated at a SIP account
RegistrationStateChanged
registration state change. Set the SIP registration in Services / SIP 1 and SIP 2.
Registration gets changed whenever the intercom is switched on, configuration is
changed or registrar connection gets lost, for example.
Input parameters
– select the account for which events are to be monitored.
Account
Valid values:
1 – account 1
2 – account 2
Any – any account
The parameter is optional, the default value is
.
Any
– set the registration state that generates the event.
State
Valid values:
– intercom not registered
Unregistered
– registration in progress
Registering
– intercom is registered
Registered
– unregistration in progress
Unregistering
– any state change
Any
The parameter is optional, the default value is
.
Any
Output parameters
Event – the Event invoke connected Event or Action.
Account – select the account for which events are to be monitored.
State – set the registration state that generates the event.
Example
Event generated when the intercom has been unregistered (whenever the registrar
failed to respond to a periodical registration request):
Summary of Contents for IP series
Page 1: ...www 2n cz Automation manual for 2N IP intercoms Configuration Manual Version 2 22 ...
Page 18: ...2N TELEKOMUNIKACE a s www 2n cz 18 104 Example Event generated upon detection of DTMF code ...
Page 28: ...2N TELEKOMUNIKACE a s www 2n cz 28 104 ...
Page 30: ...2N TELEKOMUNIKACE a s www 2n cz 30 104 ...
Page 33: ...2N TELEKOMUNIKACE a s www 2n cz 33 104 ...
Page 43: ...2N TELEKOMUNIKACE a s www 2n cz 43 104 ...
Page 51: ...2N TELEKOMUNIKACE a s www 2n cz 51 104 ...
Page 54: ...2N TELEKOMUNIKACE a s www 2n cz 54 104 ...
Page 57: ...2N TELEKOMUNIKACE a s www 2n cz 57 104 ...
Page 60: ...2N TELEKOMUNIKACE a s www 2n cz 60 104 ...
Page 94: ...2N TELEKOMUNIKACE a s www 2n cz 94 104 tamper switch if installed tamper ...