![2N IP series Automation Manual Download Page 52](http://html.mh-extra.com/html/2n/ip-series/ip-series_automation-manual_439915052.webp)
2N TELEKOMUNIKACE a.s., www.2n.cz
52/104
Caution
Only Basic authentication is supported.
Caution
HTTP commands use URL encoding. In the following Automation example:
1. Event.KeyPressed: Key=Any
2. Action.SendHttpRequest: Uri= <Command>; Event=1 will send a message
("%" is encoded as "% 25") after pressing the
http://192.168.1.1/message=%251
quick dial button no. 1.
Button to be
pressed
Format in Formatter
Request to be sent
Quick dial 1
http://10.27.1.6
/message={1}
http://10.27.1.6/message=%251 ("%" is
encoded as "%25")
Keypad 1
http://10.27.1.6
/message={1}
http://10.27.1.6/message=1
Quick dial 1
http://10.27.1.6/mess?
age={1}
http://10.27.1.6/mess?age=%251
Keypad 1
http://10.27.1.6/mess?
age={1}
http://10.27.1.6/mess?age=1
Summary of Contents for IP series
Page 1: ...www 2n cz Automation manual for 2N IP intercoms Configuration Manual Version 2 22 ...
Page 18: ...2N TELEKOMUNIKACE a s www 2n cz 18 104 Example Event generated upon detection of DTMF code ...
Page 28: ...2N TELEKOMUNIKACE a s www 2n cz 28 104 ...
Page 30: ...2N TELEKOMUNIKACE a s www 2n cz 30 104 ...
Page 33: ...2N TELEKOMUNIKACE a s www 2n cz 33 104 ...
Page 43: ...2N TELEKOMUNIKACE a s www 2n cz 43 104 ...
Page 51: ...2N TELEKOMUNIKACE a s www 2n cz 51 104 ...
Page 54: ...2N TELEKOMUNIKACE a s www 2n cz 54 104 ...
Page 57: ...2N TELEKOMUNIKACE a s www 2n cz 57 104 ...
Page 60: ...2N TELEKOMUNIKACE a s www 2n cz 60 104 ...
Page 94: ...2N TELEKOMUNIKACE a s www 2n cz 94 104 tamper switch if installed tamper ...