2N TELEKOMUNIKACE a.s., www.2n.cz
29/104
InputChanged
The
block defines the event generated by a change of the logic level on
InputChanged
the defined digital input.
Input parameters
Input – define the logic input.
Valid values:
tamper – tamper switch input
input1 – digital input 1
input2 – digital input 2
cr_input1 – digital input 1 on card reader
cr_input2 – digital input 2 on card reader.
There may be different lists of valid values for different
intercom
2N IP
models; refer to the Available Digital Inputs and Outputs subsection.
Edge – define the detected change on the digital input.
Valid values:
falling – falling edge, change from log. 1 to log. 0
rising – rising edge, change from log. 0 to log. 1.
The parameter is optional, the default value is
.
rising
Output parameters
Event – the Event invoke connected Event or Action.
Output – the detected ID of the input whose change was the last to generate
this event. The options correspond to the Input parameter values.
Edge – the detected edge change which was the last to generate this event. The
options are falling or rising.
Example
Event generated by disconnection of the tamper switch (device opening):
Summary of Contents for IP series
Page 1: ...www 2n cz Automation manual for 2N IP intercoms Configuration Manual Version 2 22 ...
Page 18: ...2N TELEKOMUNIKACE a s www 2n cz 18 104 Example Event generated upon detection of DTMF code ...
Page 28: ...2N TELEKOMUNIKACE a s www 2n cz 28 104 ...
Page 30: ...2N TELEKOMUNIKACE a s www 2n cz 30 104 ...
Page 33: ...2N TELEKOMUNIKACE a s www 2n cz 33 104 ...
Page 43: ...2N TELEKOMUNIKACE a s www 2n cz 43 104 ...
Page 51: ...2N TELEKOMUNIKACE a s www 2n cz 51 104 ...
Page 54: ...2N TELEKOMUNIKACE a s www 2n cz 54 104 ...
Page 57: ...2N TELEKOMUNIKACE a s www 2n cz 57 104 ...
Page 60: ...2N TELEKOMUNIKACE a s www 2n cz 60 104 ...
Page 94: ...2N TELEKOMUNIKACE a s www 2n cz 94 104 tamper switch if installed tamper ...