Table of Programmable Parameters
37
Pulse width
Define a pulse width to be identified as one dialling pulse. If the limits are set
incorrectly, pulse dialling cannot be used.
Setting options:
10–90 ms
Default setting:
50–80 ms
Pulse delay
Define a period of time to be identified as a delay between pulses.
Setting options:
10–90 ms
Default setting:
30–60 ms
Minimum interdigit delay
Set the minimum interval between two digits dialled.
Setting options:
100–500 ms
Setting step:
1 ms
Default setting:
100 ms
On-hook timeout
Set the minimum line current discontinuation to be evaluated as hang-up by
2N
®
EasyRoute. If shorter, the discontinuation is ignored by the gateway.
Setting options:
100–1000 ms
Setting step:
1 ms
Default setting:
300 ms
Save button
Push this button to save the new settings.
Default button
Push this button to restore the default values (factory settings).
Tones
ER
Dialtone – frequency
Here set the frequency of the dialling tone in [Hz]. You can set up to two
frequencies for a dual tone. The first frequency is obligatory, the other is optional.
Setting options:
100–3,500 Hz
Setting step:
5 Hz
Default setting:
425 Hz for the first tone, the other tone is disabled.
Dialtone – modulation
Set the dialtone modulation, choosing one of the predefined dialtone patterns.
Setting options:
Continuous, 320/320/640/640 (Morse A)
Default setting:
Continuous
Busy tone– frequency
Set the busy tone frequency in [Hz]. You can set up to two frequencies for a dual
tone. The first frequency is obligatory, the other is optional.
Setting options:
100–3,500 Hz